AIM: The surgical treatment of a complex anal fistula remains controversial, although 'sphincter-saving' operations are desirable. The Gore Bio-A® Fistula Plug is a new bioprosthetic plug that has been proposed for the treatment of complex anal fistula. This study reports preliminary data following implantation of this plug. METHOD: Eleven patients with a complex anal fistula underwent insertion of Gore Bio-A® Fistula Plugs. The disc diameter and number of tubes in the plug were adapted to the fistula to allow accommodation of the disc into a submucosal pocket, and the excess tubes were trimmed. During the follow-up period, patients underwent clinical and physical examinations and three-dimensional endoanal ultrasound. RESULTS: Fistulas were high anterior transphincteric in five patients and high posterior transphincteric in six patients. All patients had a loose seton placement before plug insertion. Two, three and four tubes were inserted into the fistula plug in seven, three and one patient, respectively. The median follow-up period was 5 months. No patient reported any faecal incontinence. There was no case of early plug dislodgement. Treatment success was noted for eight (72.7%) of 11 patients at the last follow-up appointment. CONCLUSION: Implanting a Gore Bio-A® Fistula Plug is a simple, minimally invasive, safe and potentially effective procedure to treat complex anal fistula. Patient selection is fundamental for success.

Ratto, C., Gore Bio-A® Fistula Plug: a new sphincter-sparing procedure for complex anal fistula, <<COLORECTAL DISEASE>>, 2012; 14 (5): e264-e264-9. [doi:10.1111/j.1463-1318.2012.02964.x] [http://hdl.handle.net/10807/57481]

Gore Bio-A® Fistula Plug: a new sphincter-sparing procedure for complex anal fistula

Ratto, Carlo
2012

Abstract

AIM: The surgical treatment of a complex anal fistula remains controversial, although 'sphincter-saving' operations are desirable. The Gore Bio-A® Fistula Plug is a new bioprosthetic plug that has been proposed for the treatment of complex anal fistula. This study reports preliminary data following implantation of this plug. METHOD: Eleven patients with a complex anal fistula underwent insertion of Gore Bio-A® Fistula Plugs. The disc diameter and number of tubes in the plug were adapted to the fistula to allow accommodation of the disc into a submucosal pocket, and the excess tubes were trimmed. During the follow-up period, patients underwent clinical and physical examinations and three-dimensional endoanal ultrasound. RESULTS: Fistulas were high anterior transphincteric in five patients and high posterior transphincteric in six patients. All patients had a loose seton placement before plug insertion. Two, three and four tubes were inserted into the fistula plug in seven, three and one patient, respectively. The median follow-up period was 5 months. No patient reported any faecal incontinence. There was no case of early plug dislodgement. Treatment success was noted for eight (72.7%) of 11 patients at the last follow-up appointment. CONCLUSION: Implanting a Gore Bio-A® Fistula Plug is a simple, minimally invasive, safe and potentially effective procedure to treat complex anal fistula. Patient selection is fundamental for success.
2012
Inglese
Ratto, C., Gore Bio-A® Fistula Plug: a new sphincter-sparing procedure for complex anal fistula, <<COLORECTAL DISEASE>>, 2012; 14 (5): e264-e264-9. [doi:10.1111/j.1463-1318.2012.02964.x] [http://hdl.handle.net/10807/57481]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/57481
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 52
  • ???jsp.display-item.citation.isi??? 38
social impact