Restenosis and bifurcated lesions represent technically challenging lesions for percutaneous coronary interventions (PCI). Data regarding procedural and clinical outcome of re-PCI for restenosis of stented bifurcated lesions are lacking. Our aims were to evaluate angiographic and procedural results and one-year clinical outcome of PCI for restenosis of stented bifurcated lesions.
Coroleu, S., De Vita, M., Burzotta, F., Trani, C., Porto, I., Niccoli, G., Leone, A. M., Tommasino, A., Talarico, G. P., Schiavoni, G., Crea, F., Angiographic and clinical outcome of percutaneous coronary intervention for in-stent restenosis of bifurcated lesions, <<EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology>>, 2012; 8 (6): 701-707. [doi:10.4244/EIJV8I6A109] [http://hdl.handle.net/10807/40992]
Angiographic and clinical outcome of percutaneous coronary intervention for in-stent restenosis of bifurcated lesions
De Vita, Maria;Burzotta, Francesco;Trani, Carlo;Porto, Italo;Niccoli, Giampaolo;Leone, Antonio Maria;Tommasino, Antonella;Talarico, Giovanni Paolo;Schiavoni, Giovanni;Crea, Filippo
2012
Abstract
Restenosis and bifurcated lesions represent technically challenging lesions for percutaneous coronary interventions (PCI). Data regarding procedural and clinical outcome of re-PCI for restenosis of stented bifurcated lesions are lacking. Our aims were to evaluate angiographic and procedural results and one-year clinical outcome of PCI for restenosis of stented bifurcated lesions.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.