Background The aim of the present study was to evaluate early results of thoracic endovascular aortic repair (TEVAR) using the Valiant Navion™ stent graft in a “real-world” scenario. Methods All patients who underwent TEVAR with the Valiant Navion™ endograft between November 2018 and November 2019 were included in this retrospective multicenter study (six European centers). The primary endpoints were technical success, incidence of major adverse events (MAEs), access failure, deployment failure, deployment accuracy, and rate of intraoperative endoleaks (ELs). Results One hundred-sixteen patients with varying thoracic aortic diseases were included. Eighteen patients (15.5%) were treated for an off-label condition. The technical success rate was 100%, without any access or deployment failures. The proximal and distal deployment accuracy rates were 99.1% and 97.4%, respectively. There were no intraoperative MAEs, including death. Two (1.7%) type Ib ELs were detected at the first postoperative CTA, all of which were in off-label procedures and related to the short length of the sealing neck. No type III ELs were detected. The median hospitalization time was 8 days (IQR 4–12), including a median intensive care unit stay of 1 day (IQR 1–2). The in-hospital mortality rate was 4.3%. At a median follow-up time of 98 days (IQR 39–187), there were no aortic-related mortalities or new onset of endoleaks. Conclusion Our initial experience with the Valiant Navion™ endograft in a wide variety of aortic diseases showed safe early outcomes, especially for on-label procedures
Sica, S., a multicenter real-world study of the valiant NAVION stent graft, <<INTERNATIONAL JOURNAL OF CARDIOLOGY>>, 2019; 331 (1): 63-68. [doi:10.1016/j.ijcard.2020.10.064] [http://hdl.handle.net/10807/169285]
a multicenter real-world study of the valiant NAVION stent graft
Sica, Simona
Secondo
Membro del Collaboration Group
2021
Abstract
Background The aim of the present study was to evaluate early results of thoracic endovascular aortic repair (TEVAR) using the Valiant Navion™ stent graft in a “real-world” scenario. Methods All patients who underwent TEVAR with the Valiant Navion™ endograft between November 2018 and November 2019 were included in this retrospective multicenter study (six European centers). The primary endpoints were technical success, incidence of major adverse events (MAEs), access failure, deployment failure, deployment accuracy, and rate of intraoperative endoleaks (ELs). Results One hundred-sixteen patients with varying thoracic aortic diseases were included. Eighteen patients (15.5%) were treated for an off-label condition. The technical success rate was 100%, without any access or deployment failures. The proximal and distal deployment accuracy rates were 99.1% and 97.4%, respectively. There were no intraoperative MAEs, including death. Two (1.7%) type Ib ELs were detected at the first postoperative CTA, all of which were in off-label procedures and related to the short length of the sealing neck. No type III ELs were detected. The median hospitalization time was 8 days (IQR 4–12), including a median intensive care unit stay of 1 day (IQR 1–2). The in-hospital mortality rate was 4.3%. At a median follow-up time of 98 days (IQR 39–187), there were no aortic-related mortalities or new onset of endoleaks. Conclusion Our initial experience with the Valiant Navion™ endograft in a wide variety of aortic diseases showed safe early outcomes, especially for on-label proceduresI documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.