Objectives The aim of the study was to compare outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in saphenous vein graft (SVG) interventions in a case-control study with a long-term follow-up. Background Safety and efficacy of DES in SVG interventions are still controversial. Methods We performed a multicenter registry assessing clinical outcomes with DES vs. BMS. We included 311 patients (239 men, age 68 ± 8 years) who underwent percutaneous coronary interventions (PCI) of SVG lesions with DES (n = 138) or BMS (n = 173) with a 2-year follow-up. Results The two groups were similar for age, sex, main risk factors, incidence of diabetes, use of IIb/IIIa antagonists, use of aspiration devices or filters, number of stents, and total stent length. Overall, at 9 months follow-up incidence of major adverse cardiac events (MACE) and target vessel revascularization (TVR) were significantly lower in the DES group compared with the BMS group (10.9% vs. 22.0%, P = 0.014 and 8.7% vs. 19.1% in DES and BMS respectively, P = 0.015), while there was no significant difference in incidence of myocardial infarction (5.1% vs. 5.2%, P = 0.96) or death (2.2% vs. 4%, respectively, P = 0.54). However, at 24-month follow-up incidence of MACE was 29.7% in the DES group and 37.0% in BMS group (P = 0.29); incidence of TVR (23.2% vs. 28.9% P = 0.39), myocardial infarction (9.4% vs. 9.2%), death (7.2% vs. 6.9%) were also similar in the two groups. Conclusions Although DES appear safe, our findings suggest that the early benefit of DES in SVG may rapidly wane during long-term follow-up. Copyright © 2012 Wiley Periodicals, Inc.

Pasceri, V., Tarsia, G., Niccoli, G., Viceconte, N., Porto, I., Leone, A. M., Trani, C., Speciale, G., Lisanti, P., Early beneficial effects of drug-eluting stents in vein grafts wane during long term follow-up: A Case-Control Study, <<CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS>>, 2012; 80 (7): 1112-1117. [doi:10.1002/ccd.23468] [http://hdl.handle.net/10807/157268]

Early beneficial effects of drug-eluting stents in vein grafts wane during long term follow-up: A Case-Control Study

Niccoli, G.;Porto, I.;Leone, A. M.;Trani, C.;
2012

Abstract

Objectives The aim of the study was to compare outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in saphenous vein graft (SVG) interventions in a case-control study with a long-term follow-up. Background Safety and efficacy of DES in SVG interventions are still controversial. Methods We performed a multicenter registry assessing clinical outcomes with DES vs. BMS. We included 311 patients (239 men, age 68 ± 8 years) who underwent percutaneous coronary interventions (PCI) of SVG lesions with DES (n = 138) or BMS (n = 173) with a 2-year follow-up. Results The two groups were similar for age, sex, main risk factors, incidence of diabetes, use of IIb/IIIa antagonists, use of aspiration devices or filters, number of stents, and total stent length. Overall, at 9 months follow-up incidence of major adverse cardiac events (MACE) and target vessel revascularization (TVR) were significantly lower in the DES group compared with the BMS group (10.9% vs. 22.0%, P = 0.014 and 8.7% vs. 19.1% in DES and BMS respectively, P = 0.015), while there was no significant difference in incidence of myocardial infarction (5.1% vs. 5.2%, P = 0.96) or death (2.2% vs. 4%, respectively, P = 0.54). However, at 24-month follow-up incidence of MACE was 29.7% in the DES group and 37.0% in BMS group (P = 0.29); incidence of TVR (23.2% vs. 28.9% P = 0.39), myocardial infarction (9.4% vs. 9.2%), death (7.2% vs. 6.9%) were also similar in the two groups. Conclusions Although DES appear safe, our findings suggest that the early benefit of DES in SVG may rapidly wane during long-term follow-up. Copyright © 2012 Wiley Periodicals, Inc.
2012
Inglese
Pasceri, V., Tarsia, G., Niccoli, G., Viceconte, N., Porto, I., Leone, A. M., Trani, C., Speciale, G., Lisanti, P., Early beneficial effects of drug-eluting stents in vein grafts wane during long term follow-up: A Case-Control Study, <<CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS>>, 2012; 80 (7): 1112-1117. [doi:10.1002/ccd.23468] [http://hdl.handle.net/10807/157268]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/157268
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 5
social impact