BACKGROUND: Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. METHODS: All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. RESULTS: Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. CONCLUSIONS: Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal

Familiari, P., Bulajic, M., Mutignani, M., Lee, L. S., Spera, G., Spada, C., Tringali, A., Costamagna, G., Endoscopic removal of malfunctioning biliary self-expandable metallic stents, <<GASTROINTESTINAL ENDOSCOPY>>, 2005; (Volume 62, Issue 6): 903-910. [doi:10.1016/j.gie.2005.08.051] [http://hdl.handle.net/10807/113633]

Endoscopic removal of malfunctioning biliary self-expandable metallic stents

Familiari, Pietro;Mutignani, Massimiliano;Spera, Gianluca;Spada, Cristiano;Tringali, Andrea;Costamagna, Guido
2005

Abstract

BACKGROUND: Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. METHODS: All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. RESULTS: Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. CONCLUSIONS: Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal
2005
Inglese
Familiari, P., Bulajic, M., Mutignani, M., Lee, L. S., Spera, G., Spada, C., Tringali, A., Costamagna, G., Endoscopic removal of malfunctioning biliary self-expandable metallic stents, <<GASTROINTESTINAL ENDOSCOPY>>, 2005; (Volume 62, Issue 6): 903-910. [doi:10.1016/j.gie.2005.08.051] [http://hdl.handle.net/10807/113633]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/113633
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 121
  • ???jsp.display-item.citation.isi??? 93
social impact