Introduction: Our objective was to elucidate the overall diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation (AIP). Material and methods: Medline, Embase, CINAHL and The Cochrane databases were searched. The ultrasound signs explored were: loss of hypoechoic (clear) zone in the placental–uterine interface, placental lacunae, bladder wall interruption, myometrial thinning, focal exophitic mass, placental lacunar flow, subplacental vascularity, and uterovesical hypervascularity. Results: Twenty studies (3209 pregnancies) were included. Ultrasound had an overall good diagnostic accuracy in identifying the depth of placental invasion with sensitivities of 90.6%, 93.0%, 89.5%, and 81.2% for placenta accreta, increta, accreta/increta, and percreta, respectively; the corresponding specificities were 97.1%, 98.4%, 94.7%, and 98.9%. Placental lacunae had sensitivities of 74.8%, 88.6%, and 76.3% for the detection of placenta accreta, increta, and percreta, respectively. Sensitivity and specificity of loss of the clear zone in identifying placenta accreta were 74.9% and 92.0%, whereas the corresponding figures for placenta increta and percreta were 91.6% and 76.9%, and 88.1% and 71.1%. Lacunar flow had sensitivities of 81.2%, 84.3%, and 45.2% for the detection of placenta accreta, increta, and percreta respectively; the corresponding figures for specificity were 84.0%, 79.7%, and 75.3%. Sensitivity of uterovesical hypervascularity was low for the detection of placenta accreta (12.3%) but high for placenta increta (94.4%) and percreta (86.2%); the corresponding figures for specificity were 90.8%, 88.0% and 88.2%, respectively. Conclusions: Ultrasound has an overall good diagnostic accuracy in recognizing the depth and the topography of placental invasion.

Pagani, G., Cali, G., Acharya, G., Trisch, I., Palacios-Jaraquemada, J., Familiari, A., Buca, D., Manzoli, L., Flacco, M. E., Fanfani, F., Liberati, M., Scambia, G., D'Antonio, F., Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta-analysis, <<ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA>>, 2018; 97 (1): 25-37. [doi:10.1111/aogs.13238] [http://hdl.handle.net/10807/111956]

Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta-analysis

Familiari, Alessandra;Manzoli, Lamberto;Fanfani, Francesco;Scambia, Giovanni;
2018

Abstract

Introduction: Our objective was to elucidate the overall diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation (AIP). Material and methods: Medline, Embase, CINAHL and The Cochrane databases were searched. The ultrasound signs explored were: loss of hypoechoic (clear) zone in the placental–uterine interface, placental lacunae, bladder wall interruption, myometrial thinning, focal exophitic mass, placental lacunar flow, subplacental vascularity, and uterovesical hypervascularity. Results: Twenty studies (3209 pregnancies) were included. Ultrasound had an overall good diagnostic accuracy in identifying the depth of placental invasion with sensitivities of 90.6%, 93.0%, 89.5%, and 81.2% for placenta accreta, increta, accreta/increta, and percreta, respectively; the corresponding specificities were 97.1%, 98.4%, 94.7%, and 98.9%. Placental lacunae had sensitivities of 74.8%, 88.6%, and 76.3% for the detection of placenta accreta, increta, and percreta, respectively. Sensitivity and specificity of loss of the clear zone in identifying placenta accreta were 74.9% and 92.0%, whereas the corresponding figures for placenta increta and percreta were 91.6% and 76.9%, and 88.1% and 71.1%. Lacunar flow had sensitivities of 81.2%, 84.3%, and 45.2% for the detection of placenta accreta, increta, and percreta respectively; the corresponding figures for specificity were 84.0%, 79.7%, and 75.3%. Sensitivity of uterovesical hypervascularity was low for the detection of placenta accreta (12.3%) but high for placenta increta (94.4%) and percreta (86.2%); the corresponding figures for specificity were 90.8%, 88.0% and 88.2%, respectively. Conclusions: Ultrasound has an overall good diagnostic accuracy in recognizing the depth and the topography of placental invasion.
2018
Inglese
Pagani, G., Cali, G., Acharya, G., Trisch, I., Palacios-Jaraquemada, J., Familiari, A., Buca, D., Manzoli, L., Flacco, M. E., Fanfani, F., Liberati, M., Scambia, G., D'Antonio, F., Diagnostic accuracy of ultrasound in detecting the severity of abnormally invasive placentation: a systematic review and meta-analysis, <<ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA>>, 2018; 97 (1): 25-37. [doi:10.1111/aogs.13238] [http://hdl.handle.net/10807/111956]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/111956
Citazioni
  • ???jsp.display-item.citation.pmc??? 28
  • Scopus 104
  • ???jsp.display-item.citation.isi??? 91
social impact