Background and objective: Extracorporeal photopheresis (ECP) is the most represented cell therapy for treatment of cutaneous T-cell lymphoma, graft-versus host disease and organ rejection. We analyzed our experience in ECP using 2 cell separators (Cobe Spectra and Spectra Optia) focusing on leukapheretic product characteristics, UV-A irradiation procedure and entire ECP process. Materials and methods: We collected data of patients undergoing ECP between January 2012 and February 2015 in order to evaluate collection procedures performed using Cobe Spectra and Spectra Optia, mononuclear cell product, UV-A photoirradiation procedure by Pit System. Results: We performed 484 ECP procedures in 27 patients. Cobe-derived mononuclear cell products were characterized by higher cell yields while Optia-derived mononuclear cell products were characterized by smaller volume, comparable mononuclear cell content but lower erythrocytes, granulocytes, and platelets contamination. Conclusion: Our study confirms good results for both cell separators. Blood volume processed being equal, Cobe collects a number of total nucleated cells significantly higher than Optia. Optia, collecting only target cells without significant erythrocytes, granulocytes and platelets contamination, is able to collect a leukapheretic product particularly suitable for ECP.
Piccirillo, N., Putzulu, R., Massini, G., Fiore, A. G., Chiusolo, P., Sica, S., Zini Tanzi, G., Mononuclear cell collection for extracorporeal photopheresis: Concentrate characteristics for off-line UV-A irradiation procedure, <<JOURNAL OF CLINICAL APHERESIS>>, 2017; 2017 (N/A): N/A-N/A. [doi:10.1002/jca.21574] [http://hdl.handle.net/10807/111693]
Mononuclear cell collection for extracorporeal photopheresis: Concentrate characteristics for off-line UV-A irradiation procedure
Piccirillo, Nicola;Putzulu, Rossana;Massini, Giuseppina;Chiusolo, Patrizia;Sica, Simona;Zini Tanzi, Gina
2017
Abstract
Background and objective: Extracorporeal photopheresis (ECP) is the most represented cell therapy for treatment of cutaneous T-cell lymphoma, graft-versus host disease and organ rejection. We analyzed our experience in ECP using 2 cell separators (Cobe Spectra and Spectra Optia) focusing on leukapheretic product characteristics, UV-A irradiation procedure and entire ECP process. Materials and methods: We collected data of patients undergoing ECP between January 2012 and February 2015 in order to evaluate collection procedures performed using Cobe Spectra and Spectra Optia, mononuclear cell product, UV-A photoirradiation procedure by Pit System. Results: We performed 484 ECP procedures in 27 patients. Cobe-derived mononuclear cell products were characterized by higher cell yields while Optia-derived mononuclear cell products were characterized by smaller volume, comparable mononuclear cell content but lower erythrocytes, granulocytes, and platelets contamination. Conclusion: Our study confirms good results for both cell separators. Blood volume processed being equal, Cobe collects a number of total nucleated cells significantly higher than Optia. Optia, collecting only target cells without significant erythrocytes, granulocytes and platelets contamination, is able to collect a leukapheretic product particularly suitable for ECP.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.