BACKGROUND: Upper endoscopy is not routinely performed to directly detect abnormalities of the duodenal villi. The reliability of the immersion technique for assessment of duodenal villi was evaluated in a series of patients with dyspepsia. METHODS: A total of 396 patients who were to undergo standard EGD for dyspeptic symptoms were enrolled. Patients with suspected malabsorption were excluded. By performing a "modified immersion technique," duodenal villi were scored as the following: definitely present, partially present, or definitely absent. Three duodenal biopsy specimens were obtained from each patient, and villi also were scored histologically as the following: normal, partial villous pattern, or total villous atrophy. RESULTS: Sensitivity, specificity, and positive and negative predictive values of the modified immersion technique for detection of total villous atrophy were 100%, 99.7%, 85.7%, and 100%, respectively. Sensitivity, specificity, and positive and negative predictive values of modified immersion technique for detection of partial villous patterns were 75%, 99.5%, 60%, and 99.7%, respectively. Sensitivity, specificity, and positive and negative predictive values for modified immersion technique detection of any villous abnormality (partial or total villous atrophy) were 90.9%, 99.5%, 83.3%, and 99.7%, respectively. CONCLUSIONS: During standard EGD, duodenal evaluation by modified immersion technique can reliably detect abnormalities of duodenal villi. This simple diagnostic technique may be performed routinely during endoscopic exploration of duodenum

Cammarota, G., Pirozzi, E., Martino, A., Zuccala', G., Cianci, R., Cuoco, L., Ojetti, V., Landriscina, M., Montalto, M., Vecchio, F. M., Gasbarrini, G. B., Gasbarrini, A., A) Reliability of the "immersion technique" during routine upper endoscopy for detection of abnormalities of duodenal villi in patients with dyspepsia., <<GASTROINTESTINAL ENDOSCOPY>>, 2004; (Agosto): 223-228 [http://hdl.handle.net/10807/9275]

A) Reliability of the "immersion technique" during routine upper endoscopy for detection of abnormalities of duodenal villi in patients with dyspepsia.

Cammarota, Giovanni;Pirozzi, Enza;Martino, Antonio;Zuccala', Giuseppe;Cianci, Rossella;Ojetti, Veronica;Landriscina, Matteo;Montalto, Massimo;Vecchio, Fabio Maria;Gasbarrini, Giovanni Battista;Gasbarrini, Antonio
2004

Abstract

BACKGROUND: Upper endoscopy is not routinely performed to directly detect abnormalities of the duodenal villi. The reliability of the immersion technique for assessment of duodenal villi was evaluated in a series of patients with dyspepsia. METHODS: A total of 396 patients who were to undergo standard EGD for dyspeptic symptoms were enrolled. Patients with suspected malabsorption were excluded. By performing a "modified immersion technique," duodenal villi were scored as the following: definitely present, partially present, or definitely absent. Three duodenal biopsy specimens were obtained from each patient, and villi also were scored histologically as the following: normal, partial villous pattern, or total villous atrophy. RESULTS: Sensitivity, specificity, and positive and negative predictive values of the modified immersion technique for detection of total villous atrophy were 100%, 99.7%, 85.7%, and 100%, respectively. Sensitivity, specificity, and positive and negative predictive values of modified immersion technique for detection of partial villous patterns were 75%, 99.5%, 60%, and 99.7%, respectively. Sensitivity, specificity, and positive and negative predictive values for modified immersion technique detection of any villous abnormality (partial or total villous atrophy) were 90.9%, 99.5%, 83.3%, and 99.7%, respectively. CONCLUSIONS: During standard EGD, duodenal evaluation by modified immersion technique can reliably detect abnormalities of duodenal villi. This simple diagnostic technique may be performed routinely during endoscopic exploration of duodenum
2004
Inglese
Cammarota, G., Pirozzi, E., Martino, A., Zuccala', G., Cianci, R., Cuoco, L., Ojetti, V., Landriscina, M., Montalto, M., Vecchio, F. M., Gasbarrini, G. B., Gasbarrini, A., A) Reliability of the "immersion technique" during routine upper endoscopy for detection of abnormalities of duodenal villi in patients with dyspepsia., <<GASTROINTESTINAL ENDOSCOPY>>, 2004; (Agosto): 223-228 [http://hdl.handle.net/10807/9275]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/9275
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact