The main aim of this study was to examine the absolute and relative reliability of some commonly used strength imbalance indices such as concentric hamstring-toconcentric quadriceps ratio, eccentric hamstring-to-concentric quadriceps ratio and bilateral concentric and eccentric strength ratios. An additional aim was to examine the reliability of the peak torque and work of the knee extensor and flexor muscles measured using the Cybex NORM dynamometer. Eighteen physically active healthy subjects (mean ± standard deviation, age 23 ± 3 years, height 176 ± 5 cm, body mass 74 ± 8 kg) were tested three times with 96 h between sessions. Peak torque, average work, unilateral and bilateral ratios were determined at 60, 120, 180 and )60 s)1. Low (0Æ34) to moderate (0Æ87) relative reliability (intraclass correlation coefficient, ICC) was found for strength imbalance ratios with eccentric hamstringto- concentric quadriceps ratio showing the greater ICC (>0Æ80). High ICC values (0Æ90 0Æ98) were found for peak torque and average work. Absolute reliability (standard error of measurement) ranged from 3Æ2% to 8Æ7% for strength imbalance ratios and from 4Æ3% to 7Æ7% for peak torque and average work measurements. This study established the reliability of the most common strength imbalance ratios and of absolute isokinetic muscle strength assessed using the Cybex NORM

Impellizzeri, F., Bizzini, M., Rampinini, E., Cereda, F., Maffiuletti, N., Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer, <<CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING>>, 2008; (2008) 28 (28): 113-119. [doi:10.1111/j.1475-097X.2007.00786.x] [http://hdl.handle.net/10807/4730]

Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer

Cereda, Ferdinando;
2008

Abstract

The main aim of this study was to examine the absolute and relative reliability of some commonly used strength imbalance indices such as concentric hamstring-toconcentric quadriceps ratio, eccentric hamstring-to-concentric quadriceps ratio and bilateral concentric and eccentric strength ratios. An additional aim was to examine the reliability of the peak torque and work of the knee extensor and flexor muscles measured using the Cybex NORM dynamometer. Eighteen physically active healthy subjects (mean ± standard deviation, age 23 ± 3 years, height 176 ± 5 cm, body mass 74 ± 8 kg) were tested three times with 96 h between sessions. Peak torque, average work, unilateral and bilateral ratios were determined at 60, 120, 180 and )60 s)1. Low (0Æ34) to moderate (0Æ87) relative reliability (intraclass correlation coefficient, ICC) was found for strength imbalance ratios with eccentric hamstringto- concentric quadriceps ratio showing the greater ICC (>0Æ80). High ICC values (0Æ90 0Æ98) were found for peak torque and average work. Absolute reliability (standard error of measurement) ranged from 3Æ2% to 8Æ7% for strength imbalance ratios and from 4Æ3% to 7Æ7% for peak torque and average work measurements. This study established the reliability of the most common strength imbalance ratios and of absolute isokinetic muscle strength assessed using the Cybex NORM
2008
Inglese
Impellizzeri, F., Bizzini, M., Rampinini, E., Cereda, F., Maffiuletti, N., Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer, <<CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING>>, 2008; (2008) 28 (28): 113-119. [doi:10.1111/j.1475-097X.2007.00786.x] [http://hdl.handle.net/10807/4730]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/4730
Citazioni
  • ???jsp.display-item.citation.pmc??? 64
  • Scopus 198
  • ???jsp.display-item.citation.isi??? 184
social impact