Objectives: To compare acute toxicity of prostate cancer image-guided hypofractionated radiotherapy (hypo-IGRT) with conventional fractionation without image-guidance (non-IGRT). To test the hypothesis that the potentially injurious effect of hypofractionation can be counterbalanced by the reduced irradiated normal tissue volume using IGRT approach. Materials and methods: One hundred seventy-nine cT1-T2N0M0 prostate cancer patients were treated within the prospective study with 70.2 Gy/26 fractions (equivalent to 84 Gy/42 fractions, α/β 1.5 Gy) using IGRT (transabdominal ultrasound, ExacTrac X-Ray system, or cone-beam computer tomography). Their prospectively collected data were compared with data of 174 patients treated to 80 Gy/40 fractions with non-IGRT. The difference between hypo-IGRT and non-IGRT cohorts included fractionation (hypofractionation vs. conventional fractionation), margins (hypo-IGRT margins: 7 mm and 3 mm, for all but posterior margins; respectively; non-IGRT margins: 10 and 5 mm, for all but posterior margins, respectively), and use of image-guidance or not. Multivariate analysis was performed to define the tumor-, patient-, and treatment-related predictors for acute toxicity. Results: All patients completed the prescribed radiotherapy course. Acute toxicity in the hypo-IGRT cohort included rectal (G1: 29.1%; G2: 11.2%; G3: 1.1%) and urinary events (G1: 33.5%; G2: 39.1%; G3: 5%). Acute toxicity in the non-IGRT patients included rectal (G1: 16.1%; G2: 6.3%) and urinary events (G1: 36.2%; G2: 20.7%; G3: 0.6%). In 1 hypo-IGRT and 2 non-IGRT patients, radiotherapy was temporarily interrupted due to acute toxicity. The incidence of mild (G1-2) rectal and bladder complications was significantly higher for hypo-IGRT (P = 0.0014 and P < 0.0001, respectively). Multivariate analysis showed that hypo-IGRT (P = 0.001) and higher PSA (P = 0.046) are correlated with higher acute urinary toxicity. No independent factor was identified for acute rectal toxicity. No significant impact of IGRT system on acute toxicity was observed. Conclusions: The acute toxicity rates were low and similar in both study groups with some increase in mild acute urinary injury in the hypo-IGRT patients (most probably due to the under-reporting in the retrospectively analyzed non-IGRT cohort). The higher incidence of acute bowel reactions observed in hypo-IGRT group was not significant in the multivariate analysis. Further investigation is warranted in order to exclude the bias due to the nonrandomized character of the study. © 2011 Elsevier Inc.

Jereczek-Fossa, B. A., Zerini, D., Fodor, C., Santoro, L., Cambria, R., Garibaldi, C., Tagaste, B., Vavassori, A., Cattani, F., Alterio, D., Gherardi, F., Serafini, F., Rocco, B. M. C., Musi, G., De Cobelli, O., Orecchia, R., Acute toxicity of image-guided hypofractionated radiotherapy for prostate cancer: Nonrandomized comparison with conventional fractionation, <<UROLOGIC ONCOLOGY>>, 2011; 29 (5): 523-532. [doi:10.1016/j.urolonc.2009.10.004] [https://hdl.handle.net/10807/345689]

Acute toxicity of image-guided hypofractionated radiotherapy for prostate cancer: Nonrandomized comparison with conventional fractionation

Rocco, Bernardo Maria Cesare;
2011

Abstract

Objectives: To compare acute toxicity of prostate cancer image-guided hypofractionated radiotherapy (hypo-IGRT) with conventional fractionation without image-guidance (non-IGRT). To test the hypothesis that the potentially injurious effect of hypofractionation can be counterbalanced by the reduced irradiated normal tissue volume using IGRT approach. Materials and methods: One hundred seventy-nine cT1-T2N0M0 prostate cancer patients were treated within the prospective study with 70.2 Gy/26 fractions (equivalent to 84 Gy/42 fractions, α/β 1.5 Gy) using IGRT (transabdominal ultrasound, ExacTrac X-Ray system, or cone-beam computer tomography). Their prospectively collected data were compared with data of 174 patients treated to 80 Gy/40 fractions with non-IGRT. The difference between hypo-IGRT and non-IGRT cohorts included fractionation (hypofractionation vs. conventional fractionation), margins (hypo-IGRT margins: 7 mm and 3 mm, for all but posterior margins; respectively; non-IGRT margins: 10 and 5 mm, for all but posterior margins, respectively), and use of image-guidance or not. Multivariate analysis was performed to define the tumor-, patient-, and treatment-related predictors for acute toxicity. Results: All patients completed the prescribed radiotherapy course. Acute toxicity in the hypo-IGRT cohort included rectal (G1: 29.1%; G2: 11.2%; G3: 1.1%) and urinary events (G1: 33.5%; G2: 39.1%; G3: 5%). Acute toxicity in the non-IGRT patients included rectal (G1: 16.1%; G2: 6.3%) and urinary events (G1: 36.2%; G2: 20.7%; G3: 0.6%). In 1 hypo-IGRT and 2 non-IGRT patients, radiotherapy was temporarily interrupted due to acute toxicity. The incidence of mild (G1-2) rectal and bladder complications was significantly higher for hypo-IGRT (P = 0.0014 and P < 0.0001, respectively). Multivariate analysis showed that hypo-IGRT (P = 0.001) and higher PSA (P = 0.046) are correlated with higher acute urinary toxicity. No independent factor was identified for acute rectal toxicity. No significant impact of IGRT system on acute toxicity was observed. Conclusions: The acute toxicity rates were low and similar in both study groups with some increase in mild acute urinary injury in the hypo-IGRT patients (most probably due to the under-reporting in the retrospectively analyzed non-IGRT cohort). The higher incidence of acute bowel reactions observed in hypo-IGRT group was not significant in the multivariate analysis. Further investigation is warranted in order to exclude the bias due to the nonrandomized character of the study. © 2011 Elsevier Inc.
2011
Inglese
Jereczek-Fossa, B. A., Zerini, D., Fodor, C., Santoro, L., Cambria, R., Garibaldi, C., Tagaste, B., Vavassori, A., Cattani, F., Alterio, D., Gherardi, F., Serafini, F., Rocco, B. M. C., Musi, G., De Cobelli, O., Orecchia, R., Acute toxicity of image-guided hypofractionated radiotherapy for prostate cancer: Nonrandomized comparison with conventional fractionation, <<UROLOGIC ONCOLOGY>>, 2011; 29 (5): 523-532. [doi:10.1016/j.urolonc.2009.10.004] [https://hdl.handle.net/10807/345689]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/345689
Citazioni
  • ???jsp.display-item.citation.pmc??? 14
  • Scopus 27
  • ???jsp.display-item.citation.isi??? ND
social impact