Background: Managing distal humeral fractures can be challenging for orthopedic surgeons. There are several treatment options for managing this type of fracture, and the treatment method for these fractures should be based on patient-related factors. In elderly patients with osteoporotic bone and severe comminution of the fracture, adequate fixation can be a major challenge for surgeons. The use of megaprosthesis has been recently proposed in traumatology as an alternative to osteosynthesis or conventional prosthesis for the management of comminuted articular fractures in elderly patients with poor bone stock. Methods: A consecutive case series of 5 patients who underwent reconstruction of the elbow joint with a trabecular hinged modular elbow megaprosthesis was reviewed retrospectively. All patients included had AO/OTA 13C2 and 13C3 fractures with metaphyseal extension and considerable bone loss of the distal humerus. The primary outcome was the evaluation of functional and clinical outcomes with the MEPS score in comminuted distal humerus fractures with metaphyseal extension and poor bone stock in elderly patients treated with elbow megaprosthesis. The secondary outcome was assessing the treatment-related complication rate of this technique in non-oncological fields. Results: Five patients were included in the study with a mean age of 82.66 ± 7.72 years at surgery. The mean MEPS value was 63 ± 24.2 at 1 month, 81 ± 23.53 at 3 months, 83 ± 24.2 at 6 months, and 84 ± 24.57 at 12 months. No intraoperative complications were recorded in our series. Of 5 patients, four patients had excellent clinical and functional outcomes. We did not encounter wound dehiscence, prosthetic joint infection, aseptic loosening, or periprosthetic fractures. Conclusions: The indication for this type of treatment must be selected and narrowed down, as it is a salvage procedure, and any failure would cause even more complex situations. Short operating times and early mobilization of the elbow are the advantages of this technique.

Caredda, M., Cianni, L., De Fazio, A., Ziranu, A., Vitiello, R., Maccauro, G., Megaprosthetic replacement in complex distal humerus fractures in elderly patients: a case series, <<JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH>>, 2024; 19 (1): N/A-N/A. [doi:10.1186/s13018-023-04465-2] [https://hdl.handle.net/10807/305023]

Megaprosthetic replacement in complex distal humerus fractures in elderly patients: a case series

Cianni, Luigi;De Fazio, Andrea;Ziranu, Antonio;Vitiello, Raffaele;Maccauro, Giulio
2024

Abstract

Background: Managing distal humeral fractures can be challenging for orthopedic surgeons. There are several treatment options for managing this type of fracture, and the treatment method for these fractures should be based on patient-related factors. In elderly patients with osteoporotic bone and severe comminution of the fracture, adequate fixation can be a major challenge for surgeons. The use of megaprosthesis has been recently proposed in traumatology as an alternative to osteosynthesis or conventional prosthesis for the management of comminuted articular fractures in elderly patients with poor bone stock. Methods: A consecutive case series of 5 patients who underwent reconstruction of the elbow joint with a trabecular hinged modular elbow megaprosthesis was reviewed retrospectively. All patients included had AO/OTA 13C2 and 13C3 fractures with metaphyseal extension and considerable bone loss of the distal humerus. The primary outcome was the evaluation of functional and clinical outcomes with the MEPS score in comminuted distal humerus fractures with metaphyseal extension and poor bone stock in elderly patients treated with elbow megaprosthesis. The secondary outcome was assessing the treatment-related complication rate of this technique in non-oncological fields. Results: Five patients were included in the study with a mean age of 82.66 ± 7.72 years at surgery. The mean MEPS value was 63 ± 24.2 at 1 month, 81 ± 23.53 at 3 months, 83 ± 24.2 at 6 months, and 84 ± 24.57 at 12 months. No intraoperative complications were recorded in our series. Of 5 patients, four patients had excellent clinical and functional outcomes. We did not encounter wound dehiscence, prosthetic joint infection, aseptic loosening, or periprosthetic fractures. Conclusions: The indication for this type of treatment must be selected and narrowed down, as it is a salvage procedure, and any failure would cause even more complex situations. Short operating times and early mobilization of the elbow are the advantages of this technique.
2024
Inglese
Caredda, M., Cianni, L., De Fazio, A., Ziranu, A., Vitiello, R., Maccauro, G., Megaprosthetic replacement in complex distal humerus fractures in elderly patients: a case series, <<JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH>>, 2024; 19 (1): N/A-N/A. [doi:10.1186/s13018-023-04465-2] [https://hdl.handle.net/10807/305023]
File in questo prodotto:
File Dimensione Formato  
mega.pdf

accesso aperto

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.17 MB
Formato Adobe PDF
1.17 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/305023
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact