OBJECTIVE To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. DESIGN Prospective multicentre diagnostic accuracy study. SETTING 14 medical centres in China. PARTICIPANTS 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. MAIN OUTCOME MEASURES The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. RESULTS ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. CONCLUSION The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. TRIAL REGISTRATION ClinicalTrials.gov NCT03748563.

Jiang, X., Pan, J., Xu, Q., Song, Y., Sun, H., Peng, C., Qi, X., Qian, Y., Zou, W., Yang, Y., Jin, S., Duan, B., Wu, S., Chu, Y., Xiao, D., Hu, L., Cao, J., Dai, J., Liu, X., Xia, T., Zhou, W., Chen, T., Zhou, C., Wu, W., Liu, S., Yang, Z., Wang, F., Zhang, L., Li, C., Xu, H., Wang, J., Wei, B., Lin, Y., Deng, X., Qu, L., Shen, Y., Wang, H., Huang, Y., Bao, H., Zhang, S., Li, L., Shi, Y., Wang, X., Zou, D., Wan, X., Xu, M., Mao, H., He, C., Li, Z., Zuo, X., He, S., Xie, X., Liu, J., Yang, C., Spada, C., Li, Z., Liao, Z., Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study, <<BMJ>>, 2024; 384 (n/a): N/A-N/A. [doi:10.1136/bmj-2023-078581] [https://hdl.handle.net/10807/302202]

Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study

Spada, Cristiano;
2024

Abstract

OBJECTIVE To evaluate the diagnostic accuracy and safety of using magnetically guided capsule endoscopy with a detachable string (ds-MCE) for detecting and grading oesophagogastric varices in adults with cirrhosis. DESIGN Prospective multicentre diagnostic accuracy study. SETTING 14 medical centres in China. PARTICIPANTS 607 adults (>18 years) with cirrhosis recruited between 7 January 2021 and 25 August 2022. Participants underwent ds-MCE (index test), followed by oesophagogastroduodenoscopy (OGD, reference test) within 48 hours. The participants were divided into development and validation cohorts in a ratio of 2:1. MAIN OUTCOME MEASURES The primary outcomes were the sensitivity and specificity of ds-MCE in detecting oesophagogastric varices compared with OGD. Secondary outcomes included the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices and the diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices. RESULTS ds-MCE and OGD examinations were completed in 582 (95.9%) of the 607 participants. Using OGD as the reference standard, ds-MCE had a sensitivity of 97.5% (95% confidence interval 95.5% to 98.7%) and specificity of 97.8% (94.4% to 99.1%) for detecting oesophagogastric varices (both P<0.001 compared with a prespecified 85% threshold). When using the optimal 18% threshold for luminal circumference of the oesophagus derived from the development cohort (n=393), the sensitivity and specificity of ds-MCE for detecting high risk oesophageal varices in the validation cohort (n=189) were 95.8% (89.7% to 98.4%) and 94.7% (88.2% to 97.7%), respectively. The diagnostic accuracy of ds-MCE for detecting high risk oesophagogastric varices, oesophageal varices, and gastric varices was 96.3% (92.6% to 98.2%), 96.9% (95.2% to 98.0%), and 96.7% (95.0% to 97.9%), respectively. Two serious adverse events occurred with OGD but none with ds-MCE. CONCLUSION The findings of this study suggest that ds-MCE is a highly accurate and safe diagnostic tool for detecting and grading oesophagogastric varices and is a promising alternative to OGD for screening and surveillance of oesophagogastric varices in patients with cirrhosis. TRIAL REGISTRATION ClinicalTrials.gov NCT03748563.
2024
Inglese
BMJ
Jiang, X., Pan, J., Xu, Q., Song, Y., Sun, H., Peng, C., Qi, X., Qian, Y., Zou, W., Yang, Y., Jin, S., Duan, B., Wu, S., Chu, Y., Xiao, D., Hu, L., Cao, J., Dai, J., Liu, X., Xia, T., Zhou, W., Chen, T., Zhou, C., Wu, W., Liu, S., Yang, Z., Wang, F., Zhang, L., Li, C., Xu, H., Wang, J., Wei, B., Lin, Y., Deng, X., Qu, L., Shen, Y., Wang, H., Huang, Y., Bao, H., Zhang, S., Li, L., Shi, Y., Wang, X., Zou, D., Wan, X., Xu, M., Mao, H., He, C., Li, Z., Zuo, X., He, S., Xie, X., Liu, J., Yang, C., Spada, C., Li, Z., Liao, Z., Diagnostic accuracy of magnetically guided capsule endoscopy with a detachable string for detecting oesophagogastric varices in adults with cirrhosis: prospective multicentre study, <<BMJ>>, 2024; 384 (n/a): N/A-N/A. [doi:10.1136/bmj-2023-078581] [https://hdl.handle.net/10807/302202]
File in questo prodotto:
File Dimensione Formato  
bmj-2023-078581.full.pdf

accesso aperto

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.15 MB
Formato Adobe PDF
1.15 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/302202
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact