Introduction: Agarose gel-based conventional and real-time allele-specific polymerase chain reaction (AS-PCR) assays are currently used for sensitive detection and quantification of MYD88 L265P mutation. Visual inspection of an agarose gel can often be ambiguous. We propose a new allele-specific quantification PCR (AS-qPCR) assay, PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay, that uses Intercalating Nucleic Acid (INA®) technology for increased affinity and specificity. Methods: This study compares PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay with conventional AS-PCR. We included a total of 102 peripheral and bone marrow blood samples from 94 patients with a lymphoproliferative disorder. Droplet digital PCR (ddPCR) was used as a third method in case of discrepancy. Results: A positive percent agreement of 100% (95% CI 0.92–1.0) and a negative percent agreement of 98% (95% CI 0.90–1.0) were found between the conventional AS-PCR and the AS-qPCR methods. Including the ddPCR results to validate the discrepant cases, the sensitivity and specificity of PlentiPlex™ MYD88 Waldenström lymphoma qPCR Assay were 1.0 (95% CI 0.97–1.0) and 1.0 (95% CI 0.96–1.0), respectively. Conclusion: Our data demonstrate that PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay is a fast, highly sensitive, and specific method for the detection of MYD88 L265P compared with conventional AS-PCR.
Viscovo, M., Clemmensen, M. D. L., Fosso, F., Maiolo, E., Autore, F., Laurenti, L., Hohaus, S., Chiusolo, P., PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay: A highly sensitive method for detection of MYD88 L265P mutation, <<INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY>>, 2024; (N/A): N/A-N/A. [doi:10.1111/ijlh.14255] [https://hdl.handle.net/10807/274509]
PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay: A highly sensitive method for detection of MYD88 L265P mutation
Viscovo, Marcello;Autore, Francesco;Laurenti, Luca;Hohaus, Stefan;Chiusolo, Patrizia
2024
Abstract
Introduction: Agarose gel-based conventional and real-time allele-specific polymerase chain reaction (AS-PCR) assays are currently used for sensitive detection and quantification of MYD88 L265P mutation. Visual inspection of an agarose gel can often be ambiguous. We propose a new allele-specific quantification PCR (AS-qPCR) assay, PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay, that uses Intercalating Nucleic Acid (INA®) technology for increased affinity and specificity. Methods: This study compares PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay with conventional AS-PCR. We included a total of 102 peripheral and bone marrow blood samples from 94 patients with a lymphoproliferative disorder. Droplet digital PCR (ddPCR) was used as a third method in case of discrepancy. Results: A positive percent agreement of 100% (95% CI 0.92–1.0) and a negative percent agreement of 98% (95% CI 0.90–1.0) were found between the conventional AS-PCR and the AS-qPCR methods. Including the ddPCR results to validate the discrepant cases, the sensitivity and specificity of PlentiPlex™ MYD88 Waldenström lymphoma qPCR Assay were 1.0 (95% CI 0.97–1.0) and 1.0 (95% CI 0.96–1.0), respectively. Conclusion: Our data demonstrate that PlentiPlex™ MYD88 Waldenström lymphoma qPCR assay is a fast, highly sensitive, and specific method for the detection of MYD88 L265P compared with conventional AS-PCR.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.