Objectives The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system.Methods The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis.Results 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (kappa 0.39-0.71) and intraobserver reliability good to excellent (kappa 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes).Conclusions We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.

Naredo, E., D'Agostino, M. A., Terslev, L., Pineda, C., Miguel, M. I., Blasi, J., Bruyn, G. A., Kortekaas, M. C., Mandl, P., Nestorova, R., Szkudlarek, M., Todorov, P., Vlad, V., Wong, P., Bakewell, C., Filippucci, E., Zabotti, A., Micu, M., Vreju, F., Mortada, M., Mendonça, J. A., Guillen-Astete, C. A., Olivas-Vergara, O., Iagnocco, A., Hanova, P., Tinazzi, I., Balint, P. V., Aydin, S. Z., Kane, D., Keen, H., Kaeley, G. S., Möller, I., Validation and incorporation of digital entheses into a preliminary GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis, <<ANNALS OF THE RHEUMATIC DISEASES>>, 2024; (N/A): N/A-N/A. [doi:10.1136/ard-2023-225278] [https://hdl.handle.net/10807/274446]

Validation and incorporation of digital entheses into a preliminary GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis

D'Agostino, Maria Antonietta;
2024

Abstract

Objectives The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system.Methods The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis.Results 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (kappa 0.39-0.71) and intraobserver reliability good to excellent (kappa 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes).Conclusions We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.
2024
Inglese
Naredo, E., D'Agostino, M. A., Terslev, L., Pineda, C., Miguel, M. I., Blasi, J., Bruyn, G. A., Kortekaas, M. C., Mandl, P., Nestorova, R., Szkudlarek, M., Todorov, P., Vlad, V., Wong, P., Bakewell, C., Filippucci, E., Zabotti, A., Micu, M., Vreju, F., Mortada, M., Mendonça, J. A., Guillen-Astete, C. A., Olivas-Vergara, O., Iagnocco, A., Hanova, P., Tinazzi, I., Balint, P. V., Aydin, S. Z., Kane, D., Keen, H., Kaeley, G. S., Möller, I., Validation and incorporation of digital entheses into a preliminary GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis, <<ANNALS OF THE RHEUMATIC DISEASES>>, 2024; (N/A): N/A-N/A. [doi:10.1136/ard-2023-225278] [https://hdl.handle.net/10807/274446]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/274446
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact