Background: Transcatheter aortic valve implantation (TAVI) has become a largely used treatment for severe aortic stenosis. There are limited data, however, about predictors of long-term prognosis in this population. In this study, we assessed whether ventricular arrhythmias may predict clinical outcomes in patients undergoing TAVI. Methods and results: We performed a 24 h ECG Holter monitoring in 267 patients who underwent TAVI for severe aortic stenosis within 30 days from a successful procedure. The occurrence of frequent premature ventricular complexes (PVCs; ≥30/h), polymorphic PVCs and nonsustained ventricular tachycardia (NSVT) was obtained for each patient. Clinical outcome was obtained for 228 patients (85%), for an average follow-up of 3.5 years (range 1.0-8.6). Cardiovascular events (CVEs; cardiovascular death or resuscitated cardiac arrest) occurred in 26 patients (11.4%) and 63 patients died (27.6%). Frequent PVCs but not polymorphic PVCs and NSVT were found to be associated with CVEs at univariate analysis. Frequent PVCs were indeed found in 12 patients with (46.2%) and 35 without (17.3%) CVEs [hazard ratio 2.30; 95% confidence interval (CI) 1.03-5.09; P = 0.04], whereas polymorphic PVCs were found in 11 (42.3%) and 54 (26.7%) patients of the two groups, respectively (hazard ratio 1.44; 95% CI 0.64-3.25; P = 0.38), and NSVT in 9 (34.6%) and 43 patients of the two groups, respectively (hazard ratio 1.18; 95% CI 0.48-2.87; P = 0.72). Frequent PVCs, however, were not significantly associated with CVEs at multivariate Cox regression analysis (hazard ratio 1.53; 95% CI 0.37-6.30; P = 0.56). Both frequent PVCs, polymorphic PVCs and NSVT showed no significant association with mortality. Conclusion: In our study, the detection of frequent PVCs at Holter monitoring after TAVI was a predictor of CVEs (cardiovascular death/cardiac arrest), but this association was lost in multivariable analysis.

Cambise, N., Gnan, E., Tremamunno, S., Telesca, A., Belmusto, A., Tinti, L., Di Renzo, A., Aurigemma, C., Burzotta, F., Trani, C., Crea, F., Lanza, G. A., Impact on clinical outcome of ventricular arrhythmias in patients undergoing transcatheter aortic valve implantation, <<JOURNAL OF CARDIOVASCULAR MEDICINE>>, 2024; (Feb 13): N/A-N/A. [doi:10.2459/JCM.0000000000001596] [https://hdl.handle.net/10807/262817]

Impact on clinical outcome of ventricular arrhythmias in patients undergoing transcatheter aortic valve implantation

Cambise, Nello;Belmusto, Antonietta;Tinti, Lorenzo;Di Renzo, Antonio;Aurigemma, Cristina;Burzotta, Francesco;Trani, Carlo;Crea, Filippo;Lanza, Gaetano Antonio
2024

Abstract

Background: Transcatheter aortic valve implantation (TAVI) has become a largely used treatment for severe aortic stenosis. There are limited data, however, about predictors of long-term prognosis in this population. In this study, we assessed whether ventricular arrhythmias may predict clinical outcomes in patients undergoing TAVI. Methods and results: We performed a 24 h ECG Holter monitoring in 267 patients who underwent TAVI for severe aortic stenosis within 30 days from a successful procedure. The occurrence of frequent premature ventricular complexes (PVCs; ≥30/h), polymorphic PVCs and nonsustained ventricular tachycardia (NSVT) was obtained for each patient. Clinical outcome was obtained for 228 patients (85%), for an average follow-up of 3.5 years (range 1.0-8.6). Cardiovascular events (CVEs; cardiovascular death or resuscitated cardiac arrest) occurred in 26 patients (11.4%) and 63 patients died (27.6%). Frequent PVCs but not polymorphic PVCs and NSVT were found to be associated with CVEs at univariate analysis. Frequent PVCs were indeed found in 12 patients with (46.2%) and 35 without (17.3%) CVEs [hazard ratio 2.30; 95% confidence interval (CI) 1.03-5.09; P = 0.04], whereas polymorphic PVCs were found in 11 (42.3%) and 54 (26.7%) patients of the two groups, respectively (hazard ratio 1.44; 95% CI 0.64-3.25; P = 0.38), and NSVT in 9 (34.6%) and 43 patients of the two groups, respectively (hazard ratio 1.18; 95% CI 0.48-2.87; P = 0.72). Frequent PVCs, however, were not significantly associated with CVEs at multivariate Cox regression analysis (hazard ratio 1.53; 95% CI 0.37-6.30; P = 0.56). Both frequent PVCs, polymorphic PVCs and NSVT showed no significant association with mortality. Conclusion: In our study, the detection of frequent PVCs at Holter monitoring after TAVI was a predictor of CVEs (cardiovascular death/cardiac arrest), but this association was lost in multivariable analysis.
2024
Inglese
Cambise, N., Gnan, E., Tremamunno, S., Telesca, A., Belmusto, A., Tinti, L., Di Renzo, A., Aurigemma, C., Burzotta, F., Trani, C., Crea, F., Lanza, G. A., Impact on clinical outcome of ventricular arrhythmias in patients undergoing transcatheter aortic valve implantation, <<JOURNAL OF CARDIOVASCULAR MEDICINE>>, 2024; (Feb 13): N/A-N/A. [doi:10.2459/JCM.0000000000001596] [https://hdl.handle.net/10807/262817]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/262817
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact