Introduction: We described a case of initial unsuccessful outcome of failed macular hole treated with amniotic membrane, that resolved after amniotic membrane exchange and silicone oil injection. Case Description: a woman affected by a high myopic macular hole that had failed to close after multiple surgeries, had been treated using an amniotic membrane graft and 20% sulfur hexafluoride but, after the gas reabsorption, the macular hole was still open, and the amniotic membrane. A second surgery with a second amniotic membrane patch and silicone oil was carried out. Two weeks after the procedure the macular hole closed, and the final visual acuity improved from 20/400 to 20/100. Conclusions: In this case, a second surgery, using a new amniotic membrane graft and a longer-lasting endotamponade, closed the hole and improved the visual acuity.

Caporossi, T., Governatori, L., Verdina, T., Rizzo, S., Human amniotic membrane for failed macular hole. A case of initial unsuccessful outcome that resolved after amniotic membrane exchange, <<EUROPEAN JOURNAL OF OPHTHALMOLOGY>>, 2021; 32 (2): NP1-NP5. [doi:10.1177/11206721211058996] [https://hdl.handle.net/10807/249824]

Human amniotic membrane for failed macular hole. A case of initial unsuccessful outcome that resolved after amniotic membrane exchange

Caporossi, Tomaso;Rizzo, Stanislao
2022

Abstract

Introduction: We described a case of initial unsuccessful outcome of failed macular hole treated with amniotic membrane, that resolved after amniotic membrane exchange and silicone oil injection. Case Description: a woman affected by a high myopic macular hole that had failed to close after multiple surgeries, had been treated using an amniotic membrane graft and 20% sulfur hexafluoride but, after the gas reabsorption, the macular hole was still open, and the amniotic membrane. A second surgery with a second amniotic membrane patch and silicone oil was carried out. Two weeks after the procedure the macular hole closed, and the final visual acuity improved from 20/400 to 20/100. Conclusions: In this case, a second surgery, using a new amniotic membrane graft and a longer-lasting endotamponade, closed the hole and improved the visual acuity.
2022
Inglese
Caporossi, T., Governatori, L., Verdina, T., Rizzo, S., Human amniotic membrane for failed macular hole. A case of initial unsuccessful outcome that resolved after amniotic membrane exchange, <<EUROPEAN JOURNAL OF OPHTHALMOLOGY>>, 2021; 32 (2): NP1-NP5. [doi:10.1177/11206721211058996] [https://hdl.handle.net/10807/249824]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/249824
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 2
social impact