Objective Intraocular lens (IOL) repositioning using a closed-eye approach could be carried out in some selected cases. Our study focuses on the efficacy and safety of a IOL closed-eye repositioning technique using scleral suture, which is performed using a trocar as an intrastromal limbal guide. Methods and analysis Thirty-one eyes of 31 patients with late IOL dislocation operated on between January 2015 and May 2017 were included in this retrospective non-comparative consecutive case series study. The patients had a single-piece in-the-bag dislocation or a 3-pieces in-the-bag or out-of-the-bag dislocation. The patients underwent an anterior vitrectomy and a scleral refixation in a closed chamber using a 10/0 polypropylene suture passed through a 25 Gauge trocar inserted in the anterior chamber. Results The mean follow-up time was 19.54 months. Average preoperative best-corrected visual acuity (BCVA) was 0.73 LogMar (±0.21 SD); while average postoperative BCVA was 0.27 LogMar (±0.23 SD). Fifteen patients underwent anterior pars plana vitrectomy (PPV) while 16 patients did not; moreover, two patients underwent PPV. Six patients had an increase of postoperative intraocular pressure, two patients had postoperative decentration, two patients had postoperative cystoid macular oedema, none of the patients had major complications such as retinal detachment, choroidal detachment, malignant glaucoma, irreversible corneal decompensation and endophthalmitis. Conclusion We can affirm that our technique may be safe and useful in the case of 3-piece in-the bag or out-of the bag dislocated IOLs and also in the case of in-the-bag single-piece dislocated IOLs.

Giansanti, F., Tartaro, R., Caporossi, T., Murro, V., Savastano, A., Barca, F., Bacherini, D., Fiore, T., Cagini, C., Rizzo, S., Intraocular lens dislocation: A novel in-situ scleral refixation technique using a 25 Gauge trocar in the anterior chamber, <<BMJ OPEN OPHTHALMOLOGY>>, 2018; 3 (1): e000174-e000180. [doi:10.1136/bmjophth-2018-000174] [https://hdl.handle.net/10807/249795]

Intraocular lens dislocation: A novel in-situ scleral refixation technique using a 25 Gauge trocar in the anterior chamber

Caporossi, Tomaso;Savastano, Alfonso;Barca, Francesco;Bacherini, Daniela;Rizzo, Stanislao
2018

Abstract

Objective Intraocular lens (IOL) repositioning using a closed-eye approach could be carried out in some selected cases. Our study focuses on the efficacy and safety of a IOL closed-eye repositioning technique using scleral suture, which is performed using a trocar as an intrastromal limbal guide. Methods and analysis Thirty-one eyes of 31 patients with late IOL dislocation operated on between January 2015 and May 2017 were included in this retrospective non-comparative consecutive case series study. The patients had a single-piece in-the-bag dislocation or a 3-pieces in-the-bag or out-of-the-bag dislocation. The patients underwent an anterior vitrectomy and a scleral refixation in a closed chamber using a 10/0 polypropylene suture passed through a 25 Gauge trocar inserted in the anterior chamber. Results The mean follow-up time was 19.54 months. Average preoperative best-corrected visual acuity (BCVA) was 0.73 LogMar (±0.21 SD); while average postoperative BCVA was 0.27 LogMar (±0.23 SD). Fifteen patients underwent anterior pars plana vitrectomy (PPV) while 16 patients did not; moreover, two patients underwent PPV. Six patients had an increase of postoperative intraocular pressure, two patients had postoperative decentration, two patients had postoperative cystoid macular oedema, none of the patients had major complications such as retinal detachment, choroidal detachment, malignant glaucoma, irreversible corneal decompensation and endophthalmitis. Conclusion We can affirm that our technique may be safe and useful in the case of 3-piece in-the bag or out-of the bag dislocated IOLs and also in the case of in-the-bag single-piece dislocated IOLs.
2018
Inglese
Giansanti, F., Tartaro, R., Caporossi, T., Murro, V., Savastano, A., Barca, F., Bacherini, D., Fiore, T., Cagini, C., Rizzo, S., Intraocular lens dislocation: A novel in-situ scleral refixation technique using a 25 Gauge trocar in the anterior chamber, <<BMJ OPEN OPHTHALMOLOGY>>, 2018; 3 (1): e000174-e000180. [doi:10.1136/bmjophth-2018-000174] [https://hdl.handle.net/10807/249795]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/249795
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 5
  • ???jsp.display-item.citation.isi??? 3
social impact