: Despite the technical innovations introduced in the previous decades, open thoracoabdominal aortic aneurysm repair still represents an enormous challenge for patients and surgeons. Logically, the systemic inflammatory response resulting from these massive operations appears considerable; however, the response has never been thoroughly investigated. In addition, intraoperative adjuncts to modulate the postoperative activation of the immune system have not yet been introduced into clinical practice. We report a case of intraoperative hemadsorption during open repair of a thoracoabdominal aortic aneurysm through the introduction of a CytoSorb device (CytoSorbents Corp) in the left heart bypass circuit. The technique appeared feasible and safe and probably contributed to the good clinical outcomes.

Pascucci, F., Donati, T., Tinelli, G., Arlotta, G., Luparelli, A., Tshomba, Y., Intraoperative immunomodulation during left heart bypass in open thoracoabdominal aortic aneurysm repair, <<JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES>>, 2023; 9 (3): 101276-N/A. [doi:10.1016/j.jvscit.2023.101276] [https://hdl.handle.net/10807/249223]

Intraoperative immunomodulation during left heart bypass in open thoracoabdominal aortic aneurysm repair

Pascucci, Federico;Donati, Tommaso;Tinelli, Giovanni;Luparelli, Antonio;Tshomba, Yamume
2023

Abstract

: Despite the technical innovations introduced in the previous decades, open thoracoabdominal aortic aneurysm repair still represents an enormous challenge for patients and surgeons. Logically, the systemic inflammatory response resulting from these massive operations appears considerable; however, the response has never been thoroughly investigated. In addition, intraoperative adjuncts to modulate the postoperative activation of the immune system have not yet been introduced into clinical practice. We report a case of intraoperative hemadsorption during open repair of a thoracoabdominal aortic aneurysm through the introduction of a CytoSorb device (CytoSorbents Corp) in the left heart bypass circuit. The technique appeared feasible and safe and probably contributed to the good clinical outcomes.
2023
Inglese
Pascucci, F., Donati, T., Tinelli, G., Arlotta, G., Luparelli, A., Tshomba, Y., Intraoperative immunomodulation during left heart bypass in open thoracoabdominal aortic aneurysm repair, <<JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES>>, 2023; 9 (3): 101276-N/A. [doi:10.1016/j.jvscit.2023.101276] [https://hdl.handle.net/10807/249223]
File in questo prodotto:
File Dimensione Formato  
Intraoperative immunomodulation during left heart bypass in open thoracoabdominal aortic aneurysm repair.pdf

accesso aperto

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.08 MB
Formato Adobe PDF
1.08 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/249223
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact