For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra-and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

Gambini, G., Carla', M. M., Giannuzzi, F., Caporossi, T., De Vico, U., Savastano, A., Baldascino, A., Rizzo, C., Kilian, R., Caporossi, A., Rizzo, S., PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma, <<VISION>>, 2022; 6 (1): 12-26. [doi:10.3390/vision6010012] [https://hdl.handle.net/10807/248256]

PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma

Gambini, Gloria;Carla', Matteo Mario;Giannuzzi, Federico;Caporossi, Tomaso;De Vico, Umberto;Savastano, Alfonso;Baldascino, Antonio;Caporossi, Aldo;Rizzo, Stanislao
2022

Abstract

For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra-and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.
2022
Inglese
Gambini, G., Carla', M. M., Giannuzzi, F., Caporossi, T., De Vico, U., Savastano, A., Baldascino, A., Rizzo, C., Kilian, R., Caporossi, A., Rizzo, S., PreserFlo® MicroShunt: An Overview of This Minimally Invasive Device for Open-Angle Glaucoma, <<VISION>>, 2022; 6 (1): 12-26. [doi:10.3390/vision6010012] [https://hdl.handle.net/10807/248256]
File in questo prodotto:
File Dimensione Formato  
vision-06-00012.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.45 MB
Formato Adobe PDF
1.45 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/248256
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 25
  • ???jsp.display-item.citation.isi??? ND
social impact