The failed macular hole is a full-thickness defect involving the fovea that fails to close despite 1 or more surgeries. While many surgical options have been proposed to manage it, none of these guarantee complete anatomical success and satisfactory visual recovery. We report postoperative outcomes on 36 patients affected by failed macular hole, treated with a human amniotic membrane plug transplant. Follow-ups were performed with a standard ophthalmological examination and with advanced multimodal diagnostic imaging. Anatomical closure was achieved at 3 months in all patients. Mean best-corrected visual acuity improved statistically significantly at 6 months (p < 0.05). Through microperimetric tests, we assessed a partial recovery of the macular sensitivity on the edges of the plug. Analyzing SD-OCT images, we reported a tissutal ingrowth above the plug, and its segmentation into layers, mimicking normal retinal architecture. OCT-Angiography images non invasively analysed the retinal parafoveal capillary microvasculature; the elaboration of Adaptive Optics images showed the presence of photoreceptors at the edges of the plug. This work demonstrates not only the complete anatomical success of our technique, but also remarkable functional results, and opens the door to a greater understanding of modifications induced by the presence of a human amniotic membrane plug.

Caporossi, T., Pacini, B., Bacherini, D., Barca, F., Faraldi, F., Rizzo, S., Human amniotic membrane plug to promote failed macular hole closure, <<SCIENTIFIC REPORTS>>, 2020; 10 (1): 18264-18271. [doi:10.1038/s41598-020-75292-2] [https://hdl.handle.net/10807/247930]

Human amniotic membrane plug to promote failed macular hole closure

Caporossi, Tomaso;Bacherini, Daniela;Barca, Francesco;Rizzo, Stanislao
2020

Abstract

The failed macular hole is a full-thickness defect involving the fovea that fails to close despite 1 or more surgeries. While many surgical options have been proposed to manage it, none of these guarantee complete anatomical success and satisfactory visual recovery. We report postoperative outcomes on 36 patients affected by failed macular hole, treated with a human amniotic membrane plug transplant. Follow-ups were performed with a standard ophthalmological examination and with advanced multimodal diagnostic imaging. Anatomical closure was achieved at 3 months in all patients. Mean best-corrected visual acuity improved statistically significantly at 6 months (p < 0.05). Through microperimetric tests, we assessed a partial recovery of the macular sensitivity on the edges of the plug. Analyzing SD-OCT images, we reported a tissutal ingrowth above the plug, and its segmentation into layers, mimicking normal retinal architecture. OCT-Angiography images non invasively analysed the retinal parafoveal capillary microvasculature; the elaboration of Adaptive Optics images showed the presence of photoreceptors at the edges of the plug. This work demonstrates not only the complete anatomical success of our technique, but also remarkable functional results, and opens the door to a greater understanding of modifications induced by the presence of a human amniotic membrane plug.
2020
Inglese
Caporossi, T., Pacini, B., Bacherini, D., Barca, F., Faraldi, F., Rizzo, S., Human amniotic membrane plug to promote failed macular hole closure, <<SCIENTIFIC REPORTS>>, 2020; 10 (1): 18264-18271. [doi:10.1038/s41598-020-75292-2] [https://hdl.handle.net/10807/247930]
File in questo prodotto:
File Dimensione Formato  
s41598-020-75292-2.pdf

accesso aperto

Licenza: Creative commons
Dimensione 1.36 MB
Formato Adobe PDF
1.36 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/247930
Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 33
social impact