Development of improved devices for interventional closure of atrial septal defect and patent foramen ovale increased the number of adult patients who are being referred for transcatheter closure. We report two cases that were scheduled for patent foramen ovale closure because of a right-to-left atrial shunt detected at contrast transesophageal echocardiography in another institution and that were found to have pulmonary arteriovenous fistulas. Embolization of pulmonary arteriovenous fistulas was carried out successfully by transcatheter technique.

De Rosa, G., Chessa, M., Drago, M., Krantukov, P., Bini, M., Carminati, M., Bossone, E., Differential diagnosis between patent foramen ovale and pulmonary arteriovenous fistula in two patients with previous cryptogenic stroke caused by presumed paradoxical embolism, <<JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY>>, 2002; (Agosto): 845-846. [doi:10.1067/mje.2002.120289] [http://hdl.handle.net/10807/23862]

Differential diagnosis between patent foramen ovale and pulmonary arteriovenous fistula in two patients with previous cryptogenic stroke caused by presumed paradoxical embolism

De Rosa, Gabriella;Drago, Manuela;
2002

Abstract

Development of improved devices for interventional closure of atrial septal defect and patent foramen ovale increased the number of adult patients who are being referred for transcatheter closure. We report two cases that were scheduled for patent foramen ovale closure because of a right-to-left atrial shunt detected at contrast transesophageal echocardiography in another institution and that were found to have pulmonary arteriovenous fistulas. Embolization of pulmonary arteriovenous fistulas was carried out successfully by transcatheter technique.
2002
Inglese
De Rosa, G., Chessa, M., Drago, M., Krantukov, P., Bini, M., Carminati, M., Bossone, E., Differential diagnosis between patent foramen ovale and pulmonary arteriovenous fistula in two patients with previous cryptogenic stroke caused by presumed paradoxical embolism, <<JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY>>, 2002; (Agosto): 845-846. [doi:10.1067/mje.2002.120289] [http://hdl.handle.net/10807/23862]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/23862
Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 19
social impact