Background: Extended half-life recombinant FVIII products (EHL-rFVIIIs) have been engineered to improve the pharmacokinetic profile of FVIII, enabling better hemostatic protection with a reduced number of injections in persons with hemophilia. Previous studies showed several discrepancies in FVIII activity (FVIII:C) measurements for EHL-rFVIIIs comparing one-stage clotting assay (OSA) and chromogenic assay (CSA), although a systematic investigation of this phenomenon is still lacking. Objective: Evaluation of the accuracy and precision of measurement of all available EHL-rFVIIIs with 5 different assays both in vitro and ex vivo. Methods: Damoctocog alfa pegol, rurioctocog alfa pegol, turoctocog alfa pegol, and efmoroctocog alfa were tested with 3 OSA types: (1) aPTT-based commercial reagents with colloidal silica (Synthasil, Werfen-IL); (2) ellagic acid, Synthafax (Werfen-IL); and (3) OSA calibrated with each EHL-rFVIII product and colloidal silica. Measurements were also carried out with 2 different commercially available CSA reagents (Coamatic Factor VIII, Chromogenix-Werfen) and Trinichrom FVIII (Tcoag-Stago). A Bland-Altman analysis was performed to compare all assays. Results: The simple OSA showed significant discrepancies between the expected and measured EHL-rFVIII concentrations as CSA methods, whereas the calibrated OSA assay was accurate and precise in determining the activity of all EHL-rFVIIIs in the in vitro setting. Comparable results were found using ex vivo plasma samples. Conclusion: In this study, only OSA with a calibration curve constructed with each EHL-rFVIII product showed acceptable accuracy and precision in EHL-rFVIIIs measurements.

Lancellotti, S., Sacco, M., Tardugno, M., Mancuso, M. E., De Cristofaro, R., Measurement of extended half-life recombinant FVIII molecules: In vitro and ex vivo evidence of relevant assay discrepancies, <<RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS>>, 2023; 7 (2): 100070-100080. [doi:10.1016/j.rpth.2023.100070] [https://hdl.handle.net/10807/231849]

Measurement of extended half-life recombinant FVIII molecules: In vitro and ex vivo evidence of relevant assay discrepancies

Sacco, Monica;Tardugno, Maira;De Cristofaro, Raimondo
2023

Abstract

Background: Extended half-life recombinant FVIII products (EHL-rFVIIIs) have been engineered to improve the pharmacokinetic profile of FVIII, enabling better hemostatic protection with a reduced number of injections in persons with hemophilia. Previous studies showed several discrepancies in FVIII activity (FVIII:C) measurements for EHL-rFVIIIs comparing one-stage clotting assay (OSA) and chromogenic assay (CSA), although a systematic investigation of this phenomenon is still lacking. Objective: Evaluation of the accuracy and precision of measurement of all available EHL-rFVIIIs with 5 different assays both in vitro and ex vivo. Methods: Damoctocog alfa pegol, rurioctocog alfa pegol, turoctocog alfa pegol, and efmoroctocog alfa were tested with 3 OSA types: (1) aPTT-based commercial reagents with colloidal silica (Synthasil, Werfen-IL); (2) ellagic acid, Synthafax (Werfen-IL); and (3) OSA calibrated with each EHL-rFVIII product and colloidal silica. Measurements were also carried out with 2 different commercially available CSA reagents (Coamatic Factor VIII, Chromogenix-Werfen) and Trinichrom FVIII (Tcoag-Stago). A Bland-Altman analysis was performed to compare all assays. Results: The simple OSA showed significant discrepancies between the expected and measured EHL-rFVIII concentrations as CSA methods, whereas the calibrated OSA assay was accurate and precise in determining the activity of all EHL-rFVIIIs in the in vitro setting. Comparable results were found using ex vivo plasma samples. Conclusion: In this study, only OSA with a calibration curve constructed with each EHL-rFVIII product showed acceptable accuracy and precision in EHL-rFVIIIs measurements.
2023
Inglese
Lancellotti, S., Sacco, M., Tardugno, M., Mancuso, M. E., De Cristofaro, R., Measurement of extended half-life recombinant FVIII molecules: In vitro and ex vivo evidence of relevant assay discrepancies, <<RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS>>, 2023; 7 (2): 100070-100080. [doi:10.1016/j.rpth.2023.100070] [https://hdl.handle.net/10807/231849]
File in questo prodotto:
File Dimensione Formato  
PIIS2475037923000365.pdf

accesso aperto

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 1.95 MB
Formato Adobe PDF
1.95 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/231849
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 3
  • ???jsp.display-item.citation.isi??? ND
social impact