Background: Achieving an effective endoscopic skull base reconstruction in case of large dural defects requires specific training and can be extremely challenging. The aim of this study was to describe the development and validation of a preclinical model for cerebrospinal fluid (CSF) leak repair, which can be used for training and to test the mechanical efficacy of endoscopic skull base reconstruction. Methods: Eleven fresh-frozen cadaver heads were dissected. A catheter was inserted in the subdural space via a cervical access, which was sealed with mastic; a vertical graduated tube connected to the catheter measured intracranial pressure (ICP), while stained water was injected intracranially. After endoscopic skull base reconstruction was performed, an expert surgeon assessed its efficacy. ICP was then gradually increased until a leak was evident and CSF leak pressure value was recorded. The correlation between subjective and quantitative evaluations was investigated through Pearson and Spearman correlation tests. Results: The model was successfully tested in 11 specimens. A single, large dural defect was created in each model (transplanum-transtuberculum = 4; transplanum-transtuberculum-transsellar = 3; transclival = 3; transcribriform-transplanum = 1). Skull base reconstruction always comprised a rigid buttress with temporal fascia and/or fat. The CSF leak pressure ranged from 4 to 110 cmH2O. The correlation between expert subjective and quantitative assessment of skull base reconstruction mechanical efficacy was high (r = 0.7; rs = 0.7; p = 0.010 and p = 0.006, respectively). Conclusion: This preclinical model is simple, easily reproducible, and effective in simulating an intraoperative leak and objectively measures the CSF leak pressure point of a skull base reconstruction.

Mattavelli, D., Ferrari, M., Rampinelli, V., Schreiber, A., Buffoli, B., Deganello, A., Rodella, L. F., Fontanella, M. M., Nicolai, P., Doglietto, F., Development and validation of a preclinical model for training and assessment of cerebrospinal fluid leak repair in endoscopic skull base surgery, <<INTERNATIONAL FORUM OF ALLERGY AND RHINOLOGY>>, 2020; 10 (1): 89-96. [doi:10.1002/alr.22451] [https://hdl.handle.net/10807/230280]

Development and validation of a preclinical model for training and assessment of cerebrospinal fluid leak repair in endoscopic skull base surgery

Rodella, Luigi Fabrizio;Fontanella, Marco Maria;Doglietto, Francesco
2020

Abstract

Background: Achieving an effective endoscopic skull base reconstruction in case of large dural defects requires specific training and can be extremely challenging. The aim of this study was to describe the development and validation of a preclinical model for cerebrospinal fluid (CSF) leak repair, which can be used for training and to test the mechanical efficacy of endoscopic skull base reconstruction. Methods: Eleven fresh-frozen cadaver heads were dissected. A catheter was inserted in the subdural space via a cervical access, which was sealed with mastic; a vertical graduated tube connected to the catheter measured intracranial pressure (ICP), while stained water was injected intracranially. After endoscopic skull base reconstruction was performed, an expert surgeon assessed its efficacy. ICP was then gradually increased until a leak was evident and CSF leak pressure value was recorded. The correlation between subjective and quantitative evaluations was investigated through Pearson and Spearman correlation tests. Results: The model was successfully tested in 11 specimens. A single, large dural defect was created in each model (transplanum-transtuberculum = 4; transplanum-transtuberculum-transsellar = 3; transclival = 3; transcribriform-transplanum = 1). Skull base reconstruction always comprised a rigid buttress with temporal fascia and/or fat. The CSF leak pressure ranged from 4 to 110 cmH2O. The correlation between expert subjective and quantitative assessment of skull base reconstruction mechanical efficacy was high (r = 0.7; rs = 0.7; p = 0.010 and p = 0.006, respectively). Conclusion: This preclinical model is simple, easily reproducible, and effective in simulating an intraoperative leak and objectively measures the CSF leak pressure point of a skull base reconstruction.
2020
Inglese
Mattavelli, D., Ferrari, M., Rampinelli, V., Schreiber, A., Buffoli, B., Deganello, A., Rodella, L. F., Fontanella, M. M., Nicolai, P., Doglietto, F., Development and validation of a preclinical model for training and assessment of cerebrospinal fluid leak repair in endoscopic skull base surgery, <<INTERNATIONAL FORUM OF ALLERGY AND RHINOLOGY>>, 2020; 10 (1): 89-96. [doi:10.1002/alr.22451] [https://hdl.handle.net/10807/230280]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/230280
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 6
social impact