BACKGROUND AND STUDY AIMS: The aim of this study was to evaluate the feasibility, safety, and clinical impact of push-and-pull enteroscopy (PPE) in patients with suspected or documented small-bowel diseases, in a prospective multicenter trial in three European medical centers. PATIENTS AND METHODS: A total of 100 patients (mean age 56 +/- 16 years; range 13 - 90) were included at the three institutions between July and November 2004. The leading symptoms were: acute recurrent or chronic gastrointestinal bleeding (n = 64), polyposis syndrome (n = 8), chronic abdominal pain (n = 7), chronic diarrhea (n = 7), and others (n = 14). RESULTS: No major PPE-associated complications such as perforation, bleeding, or relevant injury to the small-bowel tissue or mesentery were encountered. Minor complications occurred in 12 %. The mean time required to carry out the procedure from the oral and anal approaches was 75 +/- 19 min (32 - 150 min). The average insertion depths into the small bowel were 200 +/- 70 cm per PPE session (220 +/- 90 cm with the oral approach and 130 +/- 80 cm with the anal approach). The average radiation exposure (including diagnostic and therapeutic interventions) was 2.1 +/- 2.4 min and 155 +/- 159 dGy/cm2. PPE was fully diagnostic in 72 % of cases. The majority of the patients (34 %) were suffering from angiodysplasias; ulcerations and erosions of various etiologies were seen in 16 %, and polyps and tumors in 13 %. The PPE findings played a role in the subsequent treatment in 62 % of the patients. Endoscopic treatments, including argon plasma coagulation, polypectomy, dilation, and foreign-body extraction, were carried out in 42 %. Medical treatment was given in 12 %, and patients were referred for surgery in 8 % of cases. CONCLUSIONS: This prospective analysis shows that PPE is safe and has a high diagnostic and therapeutic yield in patients with suspected or known small-bowel disease. PMID: 16010603 [PubMed - indexed for MEDLINE]

Ell, C., May, A., Nachbar, L., Cellier, C., Landi, B., Di Caro, S., Gasbarrini, A., ag) Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study., <<ENDOSCOPY>>, 2005; (37(7)): 613-616 [http://hdl.handle.net/10807/21082]

ag) Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study.

Di Caro, Simona;Gasbarrini, Antonio
2005

Abstract

BACKGROUND AND STUDY AIMS: The aim of this study was to evaluate the feasibility, safety, and clinical impact of push-and-pull enteroscopy (PPE) in patients with suspected or documented small-bowel diseases, in a prospective multicenter trial in three European medical centers. PATIENTS AND METHODS: A total of 100 patients (mean age 56 +/- 16 years; range 13 - 90) were included at the three institutions between July and November 2004. The leading symptoms were: acute recurrent or chronic gastrointestinal bleeding (n = 64), polyposis syndrome (n = 8), chronic abdominal pain (n = 7), chronic diarrhea (n = 7), and others (n = 14). RESULTS: No major PPE-associated complications such as perforation, bleeding, or relevant injury to the small-bowel tissue or mesentery were encountered. Minor complications occurred in 12 %. The mean time required to carry out the procedure from the oral and anal approaches was 75 +/- 19 min (32 - 150 min). The average insertion depths into the small bowel were 200 +/- 70 cm per PPE session (220 +/- 90 cm with the oral approach and 130 +/- 80 cm with the anal approach). The average radiation exposure (including diagnostic and therapeutic interventions) was 2.1 +/- 2.4 min and 155 +/- 159 dGy/cm2. PPE was fully diagnostic in 72 % of cases. The majority of the patients (34 %) were suffering from angiodysplasias; ulcerations and erosions of various etiologies were seen in 16 %, and polyps and tumors in 13 %. The PPE findings played a role in the subsequent treatment in 62 % of the patients. Endoscopic treatments, including argon plasma coagulation, polypectomy, dilation, and foreign-body extraction, were carried out in 42 %. Medical treatment was given in 12 %, and patients were referred for surgery in 8 % of cases. CONCLUSIONS: This prospective analysis shows that PPE is safe and has a high diagnostic and therapeutic yield in patients with suspected or known small-bowel disease. PMID: 16010603 [PubMed - indexed for MEDLINE]
2005
Inglese
Ell, C., May, A., Nachbar, L., Cellier, C., Landi, B., Di Caro, S., Gasbarrini, A., ag) Push-and-pull enteroscopy in the small bowel using the double-balloon technique: results of a prospective European multicenter study., <<ENDOSCOPY>>, 2005; (37(7)): 613-616 [http://hdl.handle.net/10807/21082]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/21082
Citazioni
  • ???jsp.display-item.citation.pmc??? 27
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact