A non-invasive technique has been used to record the electrical activity of the His-Purkinje System (HPS) on the body surface involving shielding, high gain band pass filtering and averaging of bipolar chest ECGs (V6-V6R). The measurements were made in the Berlin Magnetically Shielded Room (BMSR) which reduces the background noise level (almost white) to less than 0.4 microVrms (measured for a bandwidth between 0.1 Hz and 300 Hz), so that individual HPS body surface signals were limited only by patient inherent noise. Signal amplitudes greater than 1 microV were detectable in single beats. In addition, for best resolution, signal averaging was accomplished with software triggers referred to either the QRS complex or the P wave. A P-wave trigger is of most interest in clinical use because averaging techniques, even in the case of A-V blocks of different degree, can be applied.

Erne, S., Fenici, R., Hahlbohm, H., Lehmann, H., Trontelj, Z., Beat to beat surface recording and averaging of his-purkinje activity in man, <<JOURNAL OF ELECTROCARDIOLOGY>>, 1983; 16 (4): 355-362 [http://hdl.handle.net/10807/18044]

Beat to beat surface recording and averaging of his-purkinje activity in man

Fenici, Riccardo;
1983

Abstract

A non-invasive technique has been used to record the electrical activity of the His-Purkinje System (HPS) on the body surface involving shielding, high gain band pass filtering and averaging of bipolar chest ECGs (V6-V6R). The measurements were made in the Berlin Magnetically Shielded Room (BMSR) which reduces the background noise level (almost white) to less than 0.4 microVrms (measured for a bandwidth between 0.1 Hz and 300 Hz), so that individual HPS body surface signals were limited only by patient inherent noise. Signal amplitudes greater than 1 microV were detectable in single beats. In addition, for best resolution, signal averaging was accomplished with software triggers referred to either the QRS complex or the P wave. A P-wave trigger is of most interest in clinical use because averaging techniques, even in the case of A-V blocks of different degree, can be applied.
1983
Inglese
Erne, S., Fenici, R., Hahlbohm, H., Lehmann, H., Trontelj, Z., Beat to beat surface recording and averaging of his-purkinje activity in man, <<JOURNAL OF ELECTROCARDIOLOGY>>, 1983; 16 (4): 355-362 [http://hdl.handle.net/10807/18044]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/18044
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact