This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies

Fenici, R., Nenonen, J., Pesola, K., Koronen, P., Lotjonen, J., Makijarvi, M., Toivonen, L., Poutanen, V., Keto, P., Katila, T., Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography, <<PACING AND CLINICAL ELECTROPHYSIOLOGY>>, 1999; 22 (8): 1210-1220 [http://hdl.handle.net/10807/17634]

Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography

Fenici, Riccardo;
1999

Abstract

This study was performed to: (1) evaluate the accuracy of noninvasive magnetocardiographic (MCG) localization of an amagnetic stimulation catheter; (2) validate the feasibility of this multipurpose catheter; and (3) study the characteristics of cardiac evoked fields. A stimulation catheter specially designed to produce no magnetic disturbances was inserted into the heart of five patients after routine electrophysiological studies. The catheter position was documented on biplane cine x-ray images. MCG signals were then recorded in a magnetically shielded room during cardiac pacing. Noninvasive localization of the catheter's tip and stimulated depolarization was computed from measured MCG data using a moving equivalent current-dipole source in patient-specific boundary element torso models. In all five patients, the MCG localizations were anatomically in good agreement with the catheter positions defined from the x-ray images. The mean distance between the position of the tip of the catheter defined from x-ray fluoroscopy and the MCG localization was 11 +/- 4 mm. The mean three-dimensional difference between the MCG localization at the peak stimulus and the MCG localization, during the ventricular evoked response about 3 ms later, was 4 +/- 1 mm calculated from signal-averaged data. The 95% confidence interval of beat-to-beat localization of the tip of the stimulation catheter from ten consecutive beats in the patients was 4 +/- 2 mm. The propagation velocity of the equivalent current dipole between 5 and 10 ms after the peak stimulus was 0.9 +/- 0.2 m/s. The results show that the use of the amagnetic catheter is technically feasible and reliable in clinical studies. The accurate three-dimensional localization of this multipurpose catheter by multichannel MCG suggests that the method could be developed toward a useful clinical tool during electrophysiological studies
1999
Inglese
Fenici, R., Nenonen, J., Pesola, K., Koronen, P., Lotjonen, J., Makijarvi, M., Toivonen, L., Poutanen, V., Keto, P., Katila, T., Nonfluoroscopic localization of an amagnetic stimulation catheter by multichannel magnetocardiography, <<PACING AND CLINICAL ELECTROPHYSIOLOGY>>, 1999; 22 (8): 1210-1220 [http://hdl.handle.net/10807/17634]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/17634
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact