The position of a non-magnetic pacing catheter was localized non-invasively from multichannel magneto-cardiographic (MCG) measurements in five patients. A catheter specially designed to produce no magnetic disturbances was inserted in the heart after standard electrophysiological studies. Its position was recorded on cine X-ray images; thus the catheter was serving as an exactly defined current-dipole source. Magnetocardiograms were then recorded in a magnetically shielded room during cardiac pacing, and the MCG localization was performed using boundary element torso models. The MCG localizations were in good agreement with the catheter positions defined from the X-ray images; the average difference between these locations was 22±6 mm

Gronros, K., Fenici, R., Nenonen, J., Makijarvi, M., Korhonen, P., Katila, T., Magnetocardiographic localization of a non-magnetic pacing catheter, in Proceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, (Amsterdam, 31-October 03-November 1996), IEEE,Piscataway, NJ, United States, Piscataway, NJ 1996:4 1429-1430. [10.1109/IEMBS.1996.647489] [http://hdl.handle.net/10807/17628]

Magnetocardiographic localization of a non-magnetic pacing catheter

Fenici, Riccardo;
1996

Abstract

The position of a non-magnetic pacing catheter was localized non-invasively from multichannel magneto-cardiographic (MCG) measurements in five patients. A catheter specially designed to produce no magnetic disturbances was inserted in the heart after standard electrophysiological studies. Its position was recorded on cine X-ray images; thus the catheter was serving as an exactly defined current-dipole source. Magnetocardiograms were then recorded in a magnetically shielded room during cardiac pacing, and the MCG localization was performed using boundary element torso models. The MCG localizations were in good agreement with the catheter positions defined from the X-ray images; the average difference between these locations was 22±6 mm
1996
Inglese
Proceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
18th Annual International Conference of the IEEE Engineering in Medicine and Biology
Amsterdam
31-ott-1996
3-nov-1996
0-7803-3811-1
Gronros, K., Fenici, R., Nenonen, J., Makijarvi, M., Korhonen, P., Katila, T., Magnetocardiographic localization of a non-magnetic pacing catheter, in Proceedings of the 1996 18th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, (Amsterdam, 31-October 03-November 1996), IEEE,Piscataway, NJ, United States, Piscataway, NJ 1996:4 1429-1430. [10.1109/IEMBS.1996.647489] [http://hdl.handle.net/10807/17628]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/17628
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact