The first 36-channel Magnetocardiographic (MCG) system, successfully installed in the Biomagnetism Research Center, Catholic University of Rome, has been tested to evaluate the reliability of this novel instrumentation for the study of patients with coronary artery disease (CAD), in an "unshielded" laboratory for interventional and emergency cardiac care. 13 patients, with coronary disease documented by angiography, 8 patients with abnormality of non-invasive studies (exercise-ECG or SPECT), and 13 healthy controls (age-matched) were investigated at rest. Other 6 cases were investigated, before and after stress test with a standard ergometer. The sensitivity of the system was 20 fT/√Hz, at 1Hz. After morphological evaluation, quantitative analysis of magnetocardiographic repolarization parameters was performed according to Hänninen et al. and Park et al. At rest, magnetocardiographic mapping has shown abnormality of repolarization in 95.2% of CAD patients, with sensibility of 92.6%, specificity of 92.3%, and predictive value 92.3%

Fenici, R., Brisinda, D., Fenici, P., First 36-channel magnetocardiographic study of CAD patients in an unshielded laboratory for interventional and intensive cardiac care, in Lecture Notes in Computer Science 2674, (Lyon, 05-06 June 2003), Springer, Berlino 2003: 122-131 [http://hdl.handle.net/10807/17563]

First 36-channel magnetocardiographic study of CAD patients in an unshielded laboratory for interventional and intensive cardiac care

Fenici, Riccardo;Brisinda, Donatella;Fenici, Peter
2003

Abstract

The first 36-channel Magnetocardiographic (MCG) system, successfully installed in the Biomagnetism Research Center, Catholic University of Rome, has been tested to evaluate the reliability of this novel instrumentation for the study of patients with coronary artery disease (CAD), in an "unshielded" laboratory for interventional and emergency cardiac care. 13 patients, with coronary disease documented by angiography, 8 patients with abnormality of non-invasive studies (exercise-ECG or SPECT), and 13 healthy controls (age-matched) were investigated at rest. Other 6 cases were investigated, before and after stress test with a standard ergometer. The sensitivity of the system was 20 fT/√Hz, at 1Hz. After morphological evaluation, quantitative analysis of magnetocardiographic repolarization parameters was performed according to Hänninen et al. and Park et al. At rest, magnetocardiographic mapping has shown abnormality of repolarization in 95.2% of CAD patients, with sensibility of 92.6%, specificity of 92.3%, and predictive value 92.3%
2003
Inglese
Lecture Notes in Computer Science 2674
Second International Workshop, FIMH 2003
Lyon
5-giu-2003
6-giu-2003
3-540-40262-4
Fenici, R., Brisinda, D., Fenici, P., First 36-channel magnetocardiographic study of CAD patients in an unshielded laboratory for interventional and intensive cardiac care, in Lecture Notes in Computer Science 2674, (Lyon, 05-06 June 2003), Springer, Berlino 2003: 122-131 [http://hdl.handle.net/10807/17563]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/17563
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact