Clinical detection of fetal arrhythmias is generally performed by means of M-mode and pulsed Doppler echocardiography (fECHO), although this method is far from being ideal because it detects the mechanical activity, not the electrophysiological events. Several studies have shown the ability of fetal magnetocardiography (fMCG) to detect fetal arrhythmias directly. Method: we report fMCG of three patients (pts), respectively studied at the 37th, 32nd and 36th, 30th gestational week. In all patients fECHO had shown evidence of irregular fetal heart rhythm, but a satisfying cardiac visualization was impossible because of maternal obesity, or fetus in a constant prone position, or intra-uterine growth retardation and oligohydramnios. In the third patient fECHO had evidenced minor pericardial effusion and digoxin therapy was given. fMCG was recorded for 5 minutes with the flat 77-channel magnetometer (sensitivity 5 fT/Hz½) working in shielded room at ITAB (Chieti University). Independent Component Analysis (FastICA algorithm) was used to extract the fetal signal from fMCG raw data. Smoothing of the extracted fetal traces was performed, if necessary, to improve the S/N ratio Results: The quality of all reconstructed fetal traces allowed real-time beat-to-beat detection of supraventricular extrasystoles (SVE), with/or without aberrant ventricular conduction and/or atrio-ventricular block. Selective averaging of sinus and SVE helped the accurate estimate of QRS duration. Heart rate variability parameters were also computed in time and frequency domains. Conclusions: Reliable reconstruction of fetal cardiac signals allowed the non-invasive beat-to-beat detection of, even transient, fetal arrhythmias and the monitoring of antiarrhythmic therapy effects during pregnancy.

Comani, S., Liberati, M., Mantini, D., Alleva, G., Brisinda, D., Meloni, A., Fenici, R., Romani, G., Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of maternal obesity, fetal prone position, and oligohydramnios, Abstract de <<Biomag 2004>>, (Boston, Massachussetts, USA, 08-12 August 2004 ), Biomag 2004 Ltd., Boston, Massachussetts, USA 2004: 332-332 [http://hdl.handle.net/10807/17536]

Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of maternal obesity, fetal prone position, and oligohydramnios

Brisinda, Donatella;Fenici, Riccardo;
2004

Abstract

Clinical detection of fetal arrhythmias is generally performed by means of M-mode and pulsed Doppler echocardiography (fECHO), although this method is far from being ideal because it detects the mechanical activity, not the electrophysiological events. Several studies have shown the ability of fetal magnetocardiography (fMCG) to detect fetal arrhythmias directly. Method: we report fMCG of three patients (pts), respectively studied at the 37th, 32nd and 36th, 30th gestational week. In all patients fECHO had shown evidence of irregular fetal heart rhythm, but a satisfying cardiac visualization was impossible because of maternal obesity, or fetus in a constant prone position, or intra-uterine growth retardation and oligohydramnios. In the third patient fECHO had evidenced minor pericardial effusion and digoxin therapy was given. fMCG was recorded for 5 minutes with the flat 77-channel magnetometer (sensitivity 5 fT/Hz½) working in shielded room at ITAB (Chieti University). Independent Component Analysis (FastICA algorithm) was used to extract the fetal signal from fMCG raw data. Smoothing of the extracted fetal traces was performed, if necessary, to improve the S/N ratio Results: The quality of all reconstructed fetal traces allowed real-time beat-to-beat detection of supraventricular extrasystoles (SVE), with/or without aberrant ventricular conduction and/or atrio-ventricular block. Selective averaging of sinus and SVE helped the accurate estimate of QRS duration. Heart rate variability parameters were also computed in time and frequency domains. Conclusions: Reliable reconstruction of fetal cardiac signals allowed the non-invasive beat-to-beat detection of, even transient, fetal arrhythmias and the monitoring of antiarrhythmic therapy effects during pregnancy.
2004
Inglese
Proceedings of 14th International Conference on Biomagnetism Boston, USA
Biomag 2004
Boston, Massachussetts, USA
8-ago-2004
12-ago-2004
0-9759979-0-4
Comani, S., Liberati, M., Mantini, D., Alleva, G., Brisinda, D., Meloni, A., Fenici, R., Romani, G., Characterization of fetal arrhythmias by means of fetal magnetocardiography in three cases of maternal obesity, fetal prone position, and oligohydramnios, Abstract de <<Biomag 2004>>, (Boston, Massachussetts, USA, 08-12 August 2004 ), Biomag 2004 Ltd., Boston, Massachussetts, USA 2004: 332-332 [http://hdl.handle.net/10807/17536]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/17536
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact