Objective: To test the reliability of Outcome Measures in Rheumatology Clinical Trials (OMERACT) consensus-based ultrasound definitions for normal and vasculitic temporal and axillary arteries in patients with giant cell arteritis (GCA) and in controls. Methods: A preliminary 1-day meeting and a full 3-day meeting fulfilling OMERACT Ultrasound Group guidelines were held. Temporal and axillary arteries were examined at 2 timepoints by 12 sonographers on 4 patients with GCA and 2 controls. The aim was to test inter- and intrareader reliability for normal findings, halo sign, and compression sign. In both meetings, patients had established GCA. Pathology was more recent in the full meeting, which was preceded by 6 h of training. Scanning time was 15-20 min instead of 10-13 min. Results: In the preliminary exercise, interreader reliabilities were fair to moderate for the overall diagnosis of GCA (Light k 0.29-0.51), and poor to fair for identifying vasculitis in the respective anatomical segments (Light k 0.02-0.46). Intrareader reliabilities were moderate (Cohen k 0.32-0.64). In the main exercise, interreader reliability was good to excellent (Light k 0.76-0.86) for the overall diagnosis of GCA, and moderate to good (Light k 0.46-0.71) for identifying vasculitis in the respective anatomical segments. Intrareader reliability was excellent for diagnosis of GCA (Cohen k 0.91) and good (Cohen k 0.71-0.80) for the anatomical segments. Conclusion: OMERACT-derived definitions of halo and compression signs of temporal and axillary arteries are reliable in recent-onset GCA if experienced sonographers (> 300 examinations) have 15-20 min for a standardized examination with prior training and apply > 15 MHz probes.

Schafer, V. S., Chrysidis, S., Dejaco, C., Duftner, C., Iagnocco, A., Bruyn, G. A., Carrara, G., D'Agostino, M. A., De Miguel, E., Diamantopoulos, A. P., Fredberg, U., Hartung, W., Hocevar, A., Juche, A., Kermani, T. A., Koster, M. J., Lorenzen, T., Macchioni, P., Milchert, M., Dohn, U. M., Mukhtyar, C., Ponte, C., Ramiro, S., Scire, C. A., Terslev, L., Warrington, K. J., Dasgupta, B., Schmidt, W. A., Assessing vasculitis in giant cell arteritis by ultrasound: Results of OMERACT patient-based reliability exercises, <<THE JOURNAL OF RHEUMATOLOGY>>, 2018; 45 (9): 1289-1295. [doi:10.3899/jrheum.171428] [http://hdl.handle.net/10807/168520]

Assessing vasculitis in giant cell arteritis by ultrasound: Results of OMERACT patient-based reliability exercises

D'Agostino, Maria Antonietta
Membro del Collaboration Group
;
2018

Abstract

Objective: To test the reliability of Outcome Measures in Rheumatology Clinical Trials (OMERACT) consensus-based ultrasound definitions for normal and vasculitic temporal and axillary arteries in patients with giant cell arteritis (GCA) and in controls. Methods: A preliminary 1-day meeting and a full 3-day meeting fulfilling OMERACT Ultrasound Group guidelines were held. Temporal and axillary arteries were examined at 2 timepoints by 12 sonographers on 4 patients with GCA and 2 controls. The aim was to test inter- and intrareader reliability for normal findings, halo sign, and compression sign. In both meetings, patients had established GCA. Pathology was more recent in the full meeting, which was preceded by 6 h of training. Scanning time was 15-20 min instead of 10-13 min. Results: In the preliminary exercise, interreader reliabilities were fair to moderate for the overall diagnosis of GCA (Light k 0.29-0.51), and poor to fair for identifying vasculitis in the respective anatomical segments (Light k 0.02-0.46). Intrareader reliabilities were moderate (Cohen k 0.32-0.64). In the main exercise, interreader reliability was good to excellent (Light k 0.76-0.86) for the overall diagnosis of GCA, and moderate to good (Light k 0.46-0.71) for identifying vasculitis in the respective anatomical segments. Intrareader reliability was excellent for diagnosis of GCA (Cohen k 0.91) and good (Cohen k 0.71-0.80) for the anatomical segments. Conclusion: OMERACT-derived definitions of halo and compression signs of temporal and axillary arteries are reliable in recent-onset GCA if experienced sonographers (> 300 examinations) have 15-20 min for a standardized examination with prior training and apply > 15 MHz probes.
2018
Inglese
Schafer, V. S., Chrysidis, S., Dejaco, C., Duftner, C., Iagnocco, A., Bruyn, G. A., Carrara, G., D'Agostino, M. A., De Miguel, E., Diamantopoulos, A. P., Fredberg, U., Hartung, W., Hocevar, A., Juche, A., Kermani, T. A., Koster, M. J., Lorenzen, T., Macchioni, P., Milchert, M., Dohn, U. M., Mukhtyar, C., Ponte, C., Ramiro, S., Scire, C. A., Terslev, L., Warrington, K. J., Dasgupta, B., Schmidt, W. A., Assessing vasculitis in giant cell arteritis by ultrasound: Results of OMERACT patient-based reliability exercises, <<THE JOURNAL OF RHEUMATOLOGY>>, 2018; 45 (9): 1289-1295. [doi:10.3899/jrheum.171428] [http://hdl.handle.net/10807/168520]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/168520
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 41
  • ???jsp.display-item.citation.isi??? 39
social impact