Background: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. Objective: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. Methods: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR−), and area under the curve (AUC) on SROC curves. Results: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47–0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99–1.0; I2 = 99.2%), LR + and LR− of 51.44 (95% CI 9.53–277.64; I2 = 85.5%) and 0.23 (95% CI 0.04–1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. Conclusion: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.

Sirico, A., Raffone, A., Lanzone, A., Saccone, G., Travaglino, A., Sarno, L., Rizzo, G., Zullo, F., Maruotti, G. M., First trimester detection of fetal open spina bifida using BS/BSOB ratio, <<ARCHIVES OF GYNECOLOGY AND OBSTETRICS>>, 2019; 301 (2): 333-340. [doi:10.1007/s00404-019-05422-3] [http://hdl.handle.net/10807/167129]

First trimester detection of fetal open spina bifida using BS/BSOB ratio

Lanzone, A.;Rizzo, G.;
2020

Abstract

Background: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. Objective: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. Methods: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR−), and area under the curve (AUC) on SROC curves. Results: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47–0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99–1.0; I2 = 99.2%), LR + and LR− of 51.44 (95% CI 9.53–277.64; I2 = 85.5%) and 0.23 (95% CI 0.04–1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. Conclusion: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.
2020
Inglese
Sirico, A., Raffone, A., Lanzone, A., Saccone, G., Travaglino, A., Sarno, L., Rizzo, G., Zullo, F., Maruotti, G. M., First trimester detection of fetal open spina bifida using BS/BSOB ratio, <<ARCHIVES OF GYNECOLOGY AND OBSTETRICS>>, 2019; 301 (2): 333-340. [doi:10.1007/s00404-019-05422-3] [http://hdl.handle.net/10807/167129]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/167129
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 14
social impact