PURPOSE: To investigate the accuracy of Agatston scoring and potential for radiation dose reduction of a coronary artery calcium scoring (CACS) CT protocol at 100 kV with tin filtration (Sn100kV) and kV-independent iterative reconstruction, compared to standard 120 kV acquisitions. MATERIALS AND METHODS: With IRB approval and in HIPAA compliance, 114 patients (61.8 ± 9.6 years; 66 men) underwent CACS using a standard 120 kV protocol and an additional Sn100kV CACS scan. The two datasets were reconstructed using a medium sharp convolution algorithm and in addition the Sn100kV scans were reconstructed iteratively based on a kV-independent algorithm. Agatston scores and radiation dose values were compared between the Sn100kV and the standard 120 kV protocol. RESULTS: Median Agatston scores derived from the Sn100kV protocol with the kV-independent algorithm and the standard 120 kV were 21.4 (IQR, 0-173.8) and 24.7 (IQR, 0-171.1) respectively, with no significant differences (p=0.18). Agatston scores derived from the two different protocols had an excellent correlation (r = 0.99). The dose-length-product was 11.5 ± 4.1 mGy × cm using Sn100kV and 50.4 ± 24.9 mGy × cm using the standard 120 kV protocol (p < 0.01), resulting in a significantly lower (77%) effective dose at Sn100kV (0.16 ± 0.06 mSv vs. 0.71 ± 0.35 mSv, p < 0.01). Additionally, 99% of the patients were classified into the same risk category (0, 1-10, 11-100, 101-400, or >400) using the Sn100kV protocol. CONCLUSION: CACS at Sn100kV using the kV-independent iterative algorithm is feasible and provides high accuracy when compared to standard 120 kV scanning. Furthermore, radiation dose can be significantly reduced for this screening application in a priori healthy individuals.

Vingiani, V., Abadia, A., Schoepf, U., Fischer, A., Varga-Szemes, A., Sahbaee, P., Allmendinger, T., Tesche, C., Griffith, L., Marano, R., Martin, S., Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm., <<JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY>>, N/A; 2019 (N/A): N/A-N/A. [doi:10.1016/j.jcct.2019.11.006] [http://hdl.handle.net/10807/155196]

Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm.

Marano, R
Penultimo
;
2019

Abstract

PURPOSE: To investigate the accuracy of Agatston scoring and potential for radiation dose reduction of a coronary artery calcium scoring (CACS) CT protocol at 100 kV with tin filtration (Sn100kV) and kV-independent iterative reconstruction, compared to standard 120 kV acquisitions. MATERIALS AND METHODS: With IRB approval and in HIPAA compliance, 114 patients (61.8 ± 9.6 years; 66 men) underwent CACS using a standard 120 kV protocol and an additional Sn100kV CACS scan. The two datasets were reconstructed using a medium sharp convolution algorithm and in addition the Sn100kV scans were reconstructed iteratively based on a kV-independent algorithm. Agatston scores and radiation dose values were compared between the Sn100kV and the standard 120 kV protocol. RESULTS: Median Agatston scores derived from the Sn100kV protocol with the kV-independent algorithm and the standard 120 kV were 21.4 (IQR, 0-173.8) and 24.7 (IQR, 0-171.1) respectively, with no significant differences (p=0.18). Agatston scores derived from the two different protocols had an excellent correlation (r = 0.99). The dose-length-product was 11.5 ± 4.1 mGy × cm using Sn100kV and 50.4 ± 24.9 mGy × cm using the standard 120 kV protocol (p < 0.01), resulting in a significantly lower (77%) effective dose at Sn100kV (0.16 ± 0.06 mSv vs. 0.71 ± 0.35 mSv, p < 0.01). Additionally, 99% of the patients were classified into the same risk category (0, 1-10, 11-100, 101-400, or >400) using the Sn100kV protocol. CONCLUSION: CACS at Sn100kV using the kV-independent iterative algorithm is feasible and provides high accuracy when compared to standard 120 kV scanning. Furthermore, radiation dose can be significantly reduced for this screening application in a priori healthy individuals.
2019
Inglese
Vingiani, V., Abadia, A., Schoepf, U., Fischer, A., Varga-Szemes, A., Sahbaee, P., Allmendinger, T., Tesche, C., Griffith, L., Marano, R., Martin, S., Low-kV coronary artery calcium scoring with tin filtration using a kV-independent reconstruction algorithm., <<JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY>>, N/A; 2019 (N/A): N/A-N/A. [doi:10.1016/j.jcct.2019.11.006] [http://hdl.handle.net/10807/155196]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/155196
Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 18
social impact