This work investigates the accuracy of an in vivo estimation of absolute N-acetyl aspartate (NAA) concentrations by magnetic resonance spectroscopy (MRS) using cerebral water as an internal reference standard. Single-voxel, proton spectroscopy was carried out in two groups of rats (normal and diffuse head injury), using a PRESS sequence with TR = 3 s, TE = 135 ms. Fully relaxed water spectra and water-suppressed proton spectra were obtained from a 7 x 5 x 5 mm3 volume of tissue. MRI-based brain water content measurements were also performed. Following MRS, HPLC determinations of NAA were carried out. In the normal rats the MRS yielded 10.98 +/- 0.83 mmol/kg w.w. vs 10.76 +/- 0.76 for HPLC with a mean absolute difference of 0.8. In the injured rats the corresponding results were 9.41 +/- 1.78 (MRS) and 8.16 +/- 0.77 (HPLC) with a mean absolute difference of 1.66. The in vivo absolute method accurately documented the temporal NAA changes compared to the NAA/Cr approach.

Tavazzi, B., Fatouros, P., Beaumont, A., Signoretti, S., Lazzarino, G., Vagnozzi, R., Bullock, R., Marmarou, A., Comparison of NAA measures by MRS and HPLC, <<ACTA NEUROCHIRURGICA. SUPPLEMENTUM>>, 2000; (76): 35-37 [http://hdl.handle.net/10807/15359]

Comparison of NAA measures by MRS and HPLC

Tavazzi, Barbara;
2000

Abstract

This work investigates the accuracy of an in vivo estimation of absolute N-acetyl aspartate (NAA) concentrations by magnetic resonance spectroscopy (MRS) using cerebral water as an internal reference standard. Single-voxel, proton spectroscopy was carried out in two groups of rats (normal and diffuse head injury), using a PRESS sequence with TR = 3 s, TE = 135 ms. Fully relaxed water spectra and water-suppressed proton spectra were obtained from a 7 x 5 x 5 mm3 volume of tissue. MRI-based brain water content measurements were also performed. Following MRS, HPLC determinations of NAA were carried out. In the normal rats the MRS yielded 10.98 +/- 0.83 mmol/kg w.w. vs 10.76 +/- 0.76 for HPLC with a mean absolute difference of 0.8. In the injured rats the corresponding results were 9.41 +/- 1.78 (MRS) and 8.16 +/- 0.77 (HPLC) with a mean absolute difference of 1.66. The in vivo absolute method accurately documented the temporal NAA changes compared to the NAA/Cr approach.
2000
Inglese
Tavazzi, B., Fatouros, P., Beaumont, A., Signoretti, S., Lazzarino, G., Vagnozzi, R., Bullock, R., Marmarou, A., Comparison of NAA measures by MRS and HPLC, <<ACTA NEUROCHIRURGICA. SUPPLEMENTUM>>, 2000; (76): 35-37 [http://hdl.handle.net/10807/15359]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/15359
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact