Purpose: We evaluated the clinical ability of pattern electroretinogram (PERG) to detect functional losses in the affected hemifield of open-angle glaucoma patients with localized perimetric defects. Methods: Hemifield (horizontally-defined) steady-state PERGs (h-PERGs) were recorded in response to 1.7 c/deg alternating gratings from 32 eyes of 29 glaucomatous patients with a perimetric, focal one-hemifield defect, 10 eyes of 10 glaucomatous patients with a diffuse perimetric defect, and 18 eyes of 18 age-matched normal subjects. Standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SD-OCT) for retinal nerve fiber layer (RNFL) thickness also were performed. h-PERG amplitudes and ratios, calculated corresponding hemifield perimetric deviations, as well as hemiretina RNFL thicknesses were analyzed. Results: h-PERG amplitudes, perimetric deviations, and RNFL thicknesses showed losses (P < 0.001) when comparing affected with unaffected hemifields of localized glaucomatous eyes. No differences were found in h-PERG amplitudes between hemifields of normal or diffuse glaucomatous eyes. h-PERG amplitude ratios (affected/ unaffected hemifield) in localized glaucoma were lower (P < 0.001) than the ratios from normal or diffuse glaucomatous eyes. The areas under the receiver operating characteristic curves for h-PERG amplitude ratios, comparing localized-defect glaucomatous eyes with normal or diffuse glaucomatous eyes, were 0.93 and 0.91, respectively. Conclusions: h-PERG assessment showed good diagnostic accuracy to confirm localized glaucomatous defects detected perimetrically. This test may be particularly useful in cognitively impaired patients or young/nonverbal patients unable to provide reliable visual fields. Translational Relevance: h-PERG provides a sensitive objective measure to confirm.

Salgarello, T., Giudiceandrea, A., Calandriello, L., Marangoni, D., Colotto, M., Caporossi, A., Falsini, B., Pattern electroretinogram detects localized glaucoma defects, <<TRANSLATIONAL VISION SCIENCE & TECHNOLOGY>>, 2019; 7 (5): 6-N/A. [doi:10.1167/tvst.7.5.6] [http://hdl.handle.net/10807/150759]

Pattern electroretinogram detects localized glaucoma defects

Salgarello, Tommaso
Methodology
;
Giudiceandrea, Andrea;Colotto, Marco;Falsini, Benedetto
2018

Abstract

Purpose: We evaluated the clinical ability of pattern electroretinogram (PERG) to detect functional losses in the affected hemifield of open-angle glaucoma patients with localized perimetric defects. Methods: Hemifield (horizontally-defined) steady-state PERGs (h-PERGs) were recorded in response to 1.7 c/deg alternating gratings from 32 eyes of 29 glaucomatous patients with a perimetric, focal one-hemifield defect, 10 eyes of 10 glaucomatous patients with a diffuse perimetric defect, and 18 eyes of 18 age-matched normal subjects. Standard automated perimetry (SAP) and spectral-domain optical coherence tomography (SD-OCT) for retinal nerve fiber layer (RNFL) thickness also were performed. h-PERG amplitudes and ratios, calculated corresponding hemifield perimetric deviations, as well as hemiretina RNFL thicknesses were analyzed. Results: h-PERG amplitudes, perimetric deviations, and RNFL thicknesses showed losses (P < 0.001) when comparing affected with unaffected hemifields of localized glaucomatous eyes. No differences were found in h-PERG amplitudes between hemifields of normal or diffuse glaucomatous eyes. h-PERG amplitude ratios (affected/ unaffected hemifield) in localized glaucoma were lower (P < 0.001) than the ratios from normal or diffuse glaucomatous eyes. The areas under the receiver operating characteristic curves for h-PERG amplitude ratios, comparing localized-defect glaucomatous eyes with normal or diffuse glaucomatous eyes, were 0.93 and 0.91, respectively. Conclusions: h-PERG assessment showed good diagnostic accuracy to confirm localized glaucomatous defects detected perimetrically. This test may be particularly useful in cognitively impaired patients or young/nonverbal patients unable to provide reliable visual fields. Translational Relevance: h-PERG provides a sensitive objective measure to confirm.
2018
Inglese
Salgarello, T., Giudiceandrea, A., Calandriello, L., Marangoni, D., Colotto, M., Caporossi, A., Falsini, B., Pattern electroretinogram detects localized glaucoma defects, <<TRANSLATIONAL VISION SCIENCE & TECHNOLOGY>>, 2019; 7 (5): 6-N/A. [doi:10.1167/tvst.7.5.6] [http://hdl.handle.net/10807/150759]
File in questo prodotto:
File Dimensione Formato  
i2164-2591-7-5-6.pdf

accesso aperto

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 670.63 kB
Formato Adobe PDF
670.63 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/150759
Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 7
social impact