During the last two decades endoscopic skull base surgery observed a continuous technical and technological development 3D endoscopy and ultra High Definition (HD) endoscopy have provided great advances in terms of visualisation and spatial resolution. Ultra-high definition (UHD) 4K systems, recently introduced in the clinical practice, will shape next steps forward especially in skull base surgery field. Patients were operated on through transnasal transsphenoidal endoscopic approaches performed using Olympus NBI 4K UHD endoscope with a 4 mm 0° Ultra Telescope, 300 W xenon lamp (CLV-S400) predisposed for narrow band imaging (NBI) technology connected through a camera head to a high-quality control unit (OTV-S400 – VISERA 4K UHD) (Olympus Corporation, Tokyo, Japan). Two screens are used, one 31” Monitor – (LMD-X310S) and one main ultra-HD 55” screen optimised for UHD image reproduction (LMD-X550S). In selected cases, we used a navigation system (Stealthstation S7, Medtronic, Minneapolis, MN, US). We evaluated 22 pituitary adenomas (86.3% macroadenomas; 13.7% microadenomas). 50% were not functional (NF), 22.8% GH, 18.2% ACTH, 9% PRL-secreting. Three of 22 were recurrences. In 91% of cases we achieved total removal, while in 9% near total resection. A mean follow-up of 187 days and average length of hospitalisation was 3.09 ± 0.61 days. Surgical duration was 128.18± 30.74 minutes. We experienced only 1 case of intraoperative low flow fistula with no further complications. None of the cases required any post- or intraoperative blood transfusion. The visualisation and high resolution of the operative field provided a very detailed view of all anatomical structures and pathologies allowing an improvement in safety and efficacy of the surgical procedure. The operative time was similar to the standard 2D HD and 3D procedures and the physical strain was also comparable to others in terms of ergonomics and weight.

Rigante, M., La Rocca, G., Lauretti, L., D’Alessandris, G. Q., Mangiola, A., Anile, C., Olivi, A., Paludetti, G., Esperienza preliminare con endoscopio 4K: Analisi di pro e contro nella chirurgia del basicranio, <<ACTA OTORHINOLARYNGOLOGICA ITALICA>>, 2017; 37 (3): 237-241. [doi:10.14639/0392-100X-1684] [http://hdl.handle.net/10807/113998]

Esperienza preliminare con endoscopio 4K: Analisi di pro e contro nella chirurgia del basicranio

Rigante, Mario;La Rocca, Giuseppe;Lauretti, Liverana;Mangiola, Annunziato;Anile, Carmelo;Olivi, Alessandro;Paludetti, Gaetano
2017

Abstract

During the last two decades endoscopic skull base surgery observed a continuous technical and technological development 3D endoscopy and ultra High Definition (HD) endoscopy have provided great advances in terms of visualisation and spatial resolution. Ultra-high definition (UHD) 4K systems, recently introduced in the clinical practice, will shape next steps forward especially in skull base surgery field. Patients were operated on through transnasal transsphenoidal endoscopic approaches performed using Olympus NBI 4K UHD endoscope with a 4 mm 0° Ultra Telescope, 300 W xenon lamp (CLV-S400) predisposed for narrow band imaging (NBI) technology connected through a camera head to a high-quality control unit (OTV-S400 – VISERA 4K UHD) (Olympus Corporation, Tokyo, Japan). Two screens are used, one 31” Monitor – (LMD-X310S) and one main ultra-HD 55” screen optimised for UHD image reproduction (LMD-X550S). In selected cases, we used a navigation system (Stealthstation S7, Medtronic, Minneapolis, MN, US). We evaluated 22 pituitary adenomas (86.3% macroadenomas; 13.7% microadenomas). 50% were not functional (NF), 22.8% GH, 18.2% ACTH, 9% PRL-secreting. Three of 22 were recurrences. In 91% of cases we achieved total removal, while in 9% near total resection. A mean follow-up of 187 days and average length of hospitalisation was 3.09 ± 0.61 days. Surgical duration was 128.18± 30.74 minutes. We experienced only 1 case of intraoperative low flow fistula with no further complications. None of the cases required any post- or intraoperative blood transfusion. The visualisation and high resolution of the operative field provided a very detailed view of all anatomical structures and pathologies allowing an improvement in safety and efficacy of the surgical procedure. The operative time was similar to the standard 2D HD and 3D procedures and the physical strain was also comparable to others in terms of ergonomics and weight.
2017
Inglese
Rigante, M., La Rocca, G., Lauretti, L., D’Alessandris, G. Q., Mangiola, A., Anile, C., Olivi, A., Paludetti, G., Esperienza preliminare con endoscopio 4K: Analisi di pro e contro nella chirurgia del basicranio, <<ACTA OTORHINOLARYNGOLOGICA ITALICA>>, 2017; 37 (3): 237-241. [doi:10.14639/0392-100X-1684] [http://hdl.handle.net/10807/113998]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/113998
Citazioni
  • ???jsp.display-item.citation.pmc??? 9
  • Scopus 38
  • ???jsp.display-item.citation.isi??? 35
social impact