We evaluated an EPID-based in-vivo dosimetry algorithm (IVD) for complex VMAT treatments in clinical routine. 19 consecutive patients with head-and-neck tumors and treated with Elekta VMAT technique using Simultaneous Integrated Boost strategy were enrolled. In-vivo tests were evaluated by means of (i) ratio R between daily in-vivo isocenter dose and planned dose and (ii) γ-analysis between EPID integral portal images in terms of percentage of points with γ-value smaller than one (γ%) and mean γ-values (γmean), using a global 3%–3 mm criteria. Alert criteria of ±5% for R ratio, γ% < 90% and γmean > 0.67 were chosen. A total of 350 transit EPID images were acquired during the treatment fractions. The overall mean R ratio was equal to 1.002 ± 0.019 (1 SD), with 95.9% of tests within ±5%. The 2D portal images of γ-analysis showed an overall γmean of 0.42 ± 0.16 with 93.3% of tests within alert criteria, and a mean γ% equal to 92.9 ± 5.1% with 85.9% of tests within alert criteria. Relevant discrepancies were observed in three patients: a set-up error was detected for one patient and two patients showed major anatomical variations (weight loss/tumor shrinkage) in the second half of treatment. The results are supplied in quasi realtime, with IVD tests displayed after only 1 minute from the end of arc delivery. This procedure was able to detect when delivery was inconsistent with the original plans, allowing physics and medical staff to promptly act in case of major deviations between measured and planned dose.

Cilla, S., Meluccio, D., Fidanzio, A., Azario, L., Ianiro, A., Macchia, G., Digesù, C., Deodato, F., Valentini, V., Morganti, A. G., Piermattei, A., Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors, <<PHYSICA MEDICA>>, 2016; 32 (1): 52-58. [doi:10.1016/j.ejmp.2015.09.007] [http://hdl.handle.net/10807/71508]

Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors

Cilla, Savino;Fidanzio, Andrea;Azario, Luigi;Macchia, Gabriella;Deodato, Francesco;Valentini, Vincenzo;Morganti, Alessio Giuseppe;Piermattei, Angelo
2016

Abstract

We evaluated an EPID-based in-vivo dosimetry algorithm (IVD) for complex VMAT treatments in clinical routine. 19 consecutive patients with head-and-neck tumors and treated with Elekta VMAT technique using Simultaneous Integrated Boost strategy were enrolled. In-vivo tests were evaluated by means of (i) ratio R between daily in-vivo isocenter dose and planned dose and (ii) γ-analysis between EPID integral portal images in terms of percentage of points with γ-value smaller than one (γ%) and mean γ-values (γmean), using a global 3%–3 mm criteria. Alert criteria of ±5% for R ratio, γ% < 90% and γmean > 0.67 were chosen. A total of 350 transit EPID images were acquired during the treatment fractions. The overall mean R ratio was equal to 1.002 ± 0.019 (1 SD), with 95.9% of tests within ±5%. The 2D portal images of γ-analysis showed an overall γmean of 0.42 ± 0.16 with 93.3% of tests within alert criteria, and a mean γ% equal to 92.9 ± 5.1% with 85.9% of tests within alert criteria. Relevant discrepancies were observed in three patients: a set-up error was detected for one patient and two patients showed major anatomical variations (weight loss/tumor shrinkage) in the second half of treatment. The results are supplied in quasi realtime, with IVD tests displayed after only 1 minute from the end of arc delivery. This procedure was able to detect when delivery was inconsistent with the original plans, allowing physics and medical staff to promptly act in case of major deviations between measured and planned dose.
2016
Inglese
Cilla, S., Meluccio, D., Fidanzio, A., Azario, L., Ianiro, A., Macchia, G., Digesù, C., Deodato, F., Valentini, V., Morganti, A. G., Piermattei, A., Initial clinical experience with Epid-based in-vivo dosimetry for VMAT treatments of head-and-neck tumors, <<PHYSICA MEDICA>>, 2016; 32 (1): 52-58. [doi:10.1016/j.ejmp.2015.09.007] [http://hdl.handle.net/10807/71508]
File in questo prodotto:
File Dimensione Formato  
71508.pdf

non disponibili

Tipologia file ?: Versione Editoriale (PDF)
Licenza: Non specificato
Dimensione 1.53 MB
Formato Unknown
1.53 MB Unknown   Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/71508
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 33
social impact