PURPOSE: The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of (18)F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). METHODS: A comprehensive computer literature search of studies published through 30 June 2011 regarding (18)F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of (18)F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of (18)F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. RESULTS: Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of (18)F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of (18)F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of (18)F-DOPA PET or PET/CT was found. A significant increase in sensitivity of (18)F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. CONCLUSION: In patients with suspected PG (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. (18)F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind. Furthermore, SDHB gene mutations could influence (18)F-DOPA PET or PET/CT diagnostic performance.

Treglia, G., Cocciolillo, F., De Waure, C., Di Nardo, F., Gualano, M., Castaldi, P., Rufini, V., Giordano, A., Diagnostic performance of (18)F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis, <<EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING>>, 2012; (39): 1144-1153. [doi:10.1007/s00259-012-2087-y] [http://hdl.handle.net/10807/31450]

Diagnostic performance of (18)F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis

Treglia, Giorgio;Cocciolillo, Fabrizio;De Waure, Chiara;Di Nardo, Francesco;Castaldi, Paola;Rufini, Vittoria;Giordano, Alessandro
2012

Abstract

PURPOSE: The aim of this study was to systematically review and conduct a meta-analysis of published data about the diagnostic performance of (18)F-dihydroxyphenylalanine (DOPA) positron emission tomography (PET) in patients with paraganglioma (PG). METHODS: A comprehensive computer literature search of studies published through 30 June 2011 regarding (18)F-DOPA PET or PET/computed tomography (PET/CT) in patients with PG was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of (18)F-DOPA PET or PET/CT in patients with PG on a per patient- and on a per lesion-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of (18)F-DOPA PET or PET/CT in patients with PG. Furthermore, a sub-analysis taking into account the different genetic mutations in PG patients was also performed. RESULTS: Eleven studies comprising 275 patients with suspected PG were included in this meta-analysis. The pooled sensitivity of (18)F-DOPA PET and PET/CT in detecting PG was 91% [95% confidence interval (CI) 87-94%] on a per patient-based analysis and 79% (95% CI 76-81%) on a per lesion-based analysis. The pooled specificity of (18)F-DOPA PET and PET/CT in detecting PG was 95% (95% CI 86-99%) on a per patient-based analysis and 95% (95% CI 84-99%) on a per lesion-based analysis. The area under the ROC curve was 0.95 on a per patient- and 0.94 on a per lesion-based analysis. Heterogeneity between the studies about sensitivity of (18)F-DOPA PET or PET/CT was found. A significant increase in sensitivity of (18)F-DOPA PET or PET/CT was observed when a sub-analysis excluding patients with succinate dehydrogenase subunit B (SDHB) gene mutations was performed. CONCLUSION: In patients with suspected PG (18)F-DOPA PET or PET/CT demonstrated high sensitivity and specificity. (18)F-DOPA PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false-negative results should be kept in mind. Furthermore, SDHB gene mutations could influence (18)F-DOPA PET or PET/CT diagnostic performance.
2012
Inglese
Treglia, G., Cocciolillo, F., De Waure, C., Di Nardo, F., Gualano, M., Castaldi, P., Rufini, V., Giordano, A., Diagnostic performance of (18)F-dihydroxyphenylalanine positron emission tomography in patients with paraganglioma: a meta-analysis, <<EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING>>, 2012; (39): 1144-1153. [doi:10.1007/s00259-012-2087-y] [http://hdl.handle.net/10807/31450]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/31450
Citazioni
  • ???jsp.display-item.citation.pmc??? 21
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 83
social impact