Peyote, a cactus containing the hallucinogen mescaline, is used to induce altered states of consciousness in religious ceremonies or for recreational purpose. This study reports a case of an underage boy suspected of mescaline abuse. For this purpose, we analyzed a dark green liquid sample found in the bedroom of the boy whose urine and hair samples were collected shortly after the drink was found. A method by gas chromatography-mass spectrometry tandem mass spectrometry (GC-MS/MS) in positive chemical ionization mode was developed and validated in terms of linearity, specificity, accuracy, and sensitivity for mescaline determination at the low concentrations present in hair. GC-MS analysis of the liquid identified mescaline, while urine was negative; GC-MS/MS segmental hair analysis identified mescaline in the proximal segment (root to 2 cm), while the distal segments were negative. Although peyote was uncommonly encountered, its use was confirmed by segmental hair analysis that can provide long-term information about drugs use.

Gambelunghe, C., Marsili, R., Aroni, K., Bacci, M., Rossi, R., GC-MS and GC-MS/MS in PCI Mode Determination of Mescaline in Peyote Tea and in Biological Matrices, <<JOURNAL OF FORENSIC SCIENCES>>, N/A; (Agosto): N/A-N/A. [doi:10.1111/j.1556-4029.2012.02249.x] [http://hdl.handle.net/10807/30975]

GC-MS and GC-MS/MS in PCI Mode Determination of Mescaline in Peyote Tea and in Biological Matrices

Marsili, Remo;Rossi, Riccardo
2012

Abstract

Peyote, a cactus containing the hallucinogen mescaline, is used to induce altered states of consciousness in religious ceremonies or for recreational purpose. This study reports a case of an underage boy suspected of mescaline abuse. For this purpose, we analyzed a dark green liquid sample found in the bedroom of the boy whose urine and hair samples were collected shortly after the drink was found. A method by gas chromatography-mass spectrometry tandem mass spectrometry (GC-MS/MS) in positive chemical ionization mode was developed and validated in terms of linearity, specificity, accuracy, and sensitivity for mescaline determination at the low concentrations present in hair. GC-MS analysis of the liquid identified mescaline, while urine was negative; GC-MS/MS segmental hair analysis identified mescaline in the proximal segment (root to 2 cm), while the distal segments were negative. Although peyote was uncommonly encountered, its use was confirmed by segmental hair analysis that can provide long-term information about drugs use.
2012
Inglese
Gambelunghe, C., Marsili, R., Aroni, K., Bacci, M., Rossi, R., GC-MS and GC-MS/MS in PCI Mode Determination of Mescaline in Peyote Tea and in Biological Matrices, <<JOURNAL OF FORENSIC SCIENCES>>, N/A; (Agosto): N/A-N/A. [doi:10.1111/j.1556-4029.2012.02249.x] [http://hdl.handle.net/10807/30975]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/30975
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact