Background: Laparoscopic right hemicolectomy is a commonly performed procedure. Little is known on how to perform the enterotomy closure after stapled side-to-side intracorporeal anastomosis. Method: A multicentric case-controlled study has been designed to compare different ways to fashion enterotomy closure: double layer versus single layer, sewn versus stapled, and robotic versus laparoscopic approach. Furthermore, additional characteristics including sutures’ materials, interrupted versus running suture and the presence of deep corner suture has been investigated. Results: We collected data for 1092 patients who underwent right hemicolectomy at ten centers. We analyzed 176 robotic against 916 laparoscopic anastomosis: no significant differences were found in terms of bleedings (p = 0.455) and anastomotic leak (p = 0.405). We collected data from 126 laparoscopic sewn single-layer versus 641 laparoscopic sewn double-layer anastomosis: a significant reduction was recorded in terms of leaks in double-layer group (p = 0.02). About double-layer characteristics, we found a significant reduction of bleedings (p = 0.008) and leaks (p = 0.017) with a running suture; similarly, a reduction of bleedings (p = 0.001) and leaks (p = 0.005) was observed with the usage of deep corner closure. The presence of a barbed suture thread seemed to significantly reduce both bleedings (p = 0.001) and leaks (p = 0.001). We found no significant differences in terms of bleedings (p = 0.245) and anastomotic leak (p = 0.660) comparing sewn versus stapled anastomosis. Conclusions: Fashioning a stapled ileocolic intracorporeal anastomosis, we can recommend the adoption of a double-layer enterotomy closure using a running barbed suture in the first layer. Totally, stapled closure and robotic assistance have to be considered a non-inferior alternative.

Milone, M., Elmore, U., Allaix, M. E., Bianchi, P. P., Biondi, A., Boni, L., Bracale, U., Cassinotti, E., Ceccarelli, G., Corcione, F., Cuccurullo, D., Degiuli, M., De Manzini, N., D'Ugo, D., Formisano, G., Manigrasso, M., Morino, M., Palmisano, S., Persiani, R., Reddavid, R., Rondelli, F., Velotti, N., Rosati, R., De Palma, G. D., Fashioning enterotomy closure after totally laparoscopic ileocolic anastomosis for right colon cancer: a multicenter experience, <<SURGICAL ENDOSCOPY>>, 2019; 34 (2): 557-563. [doi:10.1007/s00464-019-06796-w] [http://hdl.handle.net/10807/147327]

Fashioning enterotomy closure after totally laparoscopic ileocolic anastomosis for right colon cancer: a multicenter experience

Biondi, Alberto;D'Ugo, Domenico;Persiani, Roberto;
2020

Abstract

Background: Laparoscopic right hemicolectomy is a commonly performed procedure. Little is known on how to perform the enterotomy closure after stapled side-to-side intracorporeal anastomosis. Method: A multicentric case-controlled study has been designed to compare different ways to fashion enterotomy closure: double layer versus single layer, sewn versus stapled, and robotic versus laparoscopic approach. Furthermore, additional characteristics including sutures’ materials, interrupted versus running suture and the presence of deep corner suture has been investigated. Results: We collected data for 1092 patients who underwent right hemicolectomy at ten centers. We analyzed 176 robotic against 916 laparoscopic anastomosis: no significant differences were found in terms of bleedings (p = 0.455) and anastomotic leak (p = 0.405). We collected data from 126 laparoscopic sewn single-layer versus 641 laparoscopic sewn double-layer anastomosis: a significant reduction was recorded in terms of leaks in double-layer group (p = 0.02). About double-layer characteristics, we found a significant reduction of bleedings (p = 0.008) and leaks (p = 0.017) with a running suture; similarly, a reduction of bleedings (p = 0.001) and leaks (p = 0.005) was observed with the usage of deep corner closure. The presence of a barbed suture thread seemed to significantly reduce both bleedings (p = 0.001) and leaks (p = 0.001). We found no significant differences in terms of bleedings (p = 0.245) and anastomotic leak (p = 0.660) comparing sewn versus stapled anastomosis. Conclusions: Fashioning a stapled ileocolic intracorporeal anastomosis, we can recommend the adoption of a double-layer enterotomy closure using a running barbed suture in the first layer. Totally, stapled closure and robotic assistance have to be considered a non-inferior alternative.
2020
Inglese
Milone, M., Elmore, U., Allaix, M. E., Bianchi, P. P., Biondi, A., Boni, L., Bracale, U., Cassinotti, E., Ceccarelli, G., Corcione, F., Cuccurullo, D., Degiuli, M., De Manzini, N., D'Ugo, D., Formisano, G., Manigrasso, M., Morino, M., Palmisano, S., Persiani, R., Reddavid, R., Rondelli, F., Velotti, N., Rosati, R., De Palma, G. D., Fashioning enterotomy closure after totally laparoscopic ileocolic anastomosis for right colon cancer: a multicenter experience, <<SURGICAL ENDOSCOPY>>, 2019; 34 (2): 557-563. [doi:10.1007/s00464-019-06796-w] [http://hdl.handle.net/10807/147327]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/147327
Citazioni
  • ???jsp.display-item.citation.pmc??? 12
  • Scopus 32
  • ???jsp.display-item.citation.isi??? 28
social impact