Background: Despite an increased use of non-invasive ventilatory strategies and gentle ventilation, pneumothorax remains a common complication in preterm infants. The ventilator management of infants with air leaks remains challenging in terms of both prevention and treatment. Recently the safety and efficacy of expectant management avoiding chest tube drainage to treat large air leak in preterm infants hemodynamically stable has been reported. Case presentation: In the present study, we report five cases of preterm infants with birth weight ≤ 1250 g affected by respiratory distress syndrome and treated with nasal continuous positive airway pressure as first intention. They were intubated for worsening of respiratory distress with increasing oxygen requirement and concomitant increase of respiratory rate and PCO2values due to occurrence of pneumothorax, and they were successfully treated using high-frequency oscillatory ventilation without chest tube insertion. Conclusion: In our experience high-frequency oscillatory ventilation provided a conservative management of a significant pneumothorax in preterm newborns hemodynamically stable and requiring mechanical ventilation. This approach allowed us to avoid the increasing of air leak and the insertion of chest tube drainage and all the subsequent associated risks.

Aurilia, C., Ricci, C., Tana, M., Tirone, C., Lio, A., Gambacorta, A., Paladini, A., Vento, G., Management of pneumothorax in hemodynamically stable preterm infants using high frequency oscillatory ventilation: Report of five cases, <<THE ITALIAN JOURNAL OF PEDIATRICS>>, 2017; 43 (1): 114-N/A. [doi:10.1186/s13052-017-0436-y] [http://hdl.handle.net/10807/113331]

Management of pneumothorax in hemodynamically stable preterm infants using high frequency oscillatory ventilation: Report of five cases

Aurilia, Claudia
Primo
;
Ricci, Cinzia
Secondo
;
Tana, Milena;Tirone, Chiara;Lio, Alessandra;Paladini, Angela;Vento, Giovanni
Ultimo
Conceptualization
2017

Abstract

Background: Despite an increased use of non-invasive ventilatory strategies and gentle ventilation, pneumothorax remains a common complication in preterm infants. The ventilator management of infants with air leaks remains challenging in terms of both prevention and treatment. Recently the safety and efficacy of expectant management avoiding chest tube drainage to treat large air leak in preterm infants hemodynamically stable has been reported. Case presentation: In the present study, we report five cases of preterm infants with birth weight ≤ 1250 g affected by respiratory distress syndrome and treated with nasal continuous positive airway pressure as first intention. They were intubated for worsening of respiratory distress with increasing oxygen requirement and concomitant increase of respiratory rate and PCO2values due to occurrence of pneumothorax, and they were successfully treated using high-frequency oscillatory ventilation without chest tube insertion. Conclusion: In our experience high-frequency oscillatory ventilation provided a conservative management of a significant pneumothorax in preterm newborns hemodynamically stable and requiring mechanical ventilation. This approach allowed us to avoid the increasing of air leak and the insertion of chest tube drainage and all the subsequent associated risks.
2017
Inglese
Aurilia, C., Ricci, C., Tana, M., Tirone, C., Lio, A., Gambacorta, A., Paladini, A., Vento, G., Management of pneumothorax in hemodynamically stable preterm infants using high frequency oscillatory ventilation: Report of five cases, <<THE ITALIAN JOURNAL OF PEDIATRICS>>, 2017; 43 (1): 114-N/A. [doi:10.1186/s13052-017-0436-y] [http://hdl.handle.net/10807/113331]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/10807/113331
Citazioni
  • ???jsp.display-item.citation.pmc??? 8
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 9
social impact